← Recent

AG-2024.07-107·astro-ph.IM·cross-listed: gr-qc

Precision measurements of the magnetic parameters of LISA Pathfinder test masses

Authors

  • M Armano
  • H Audley
  • J Baird
  • P Binetruy
  • M Born
  • D Bortoluzzi
  • E Castelli
  • A Cavalleri
  • A Cesarini
  • A M Cruise
  • K Danzmann
  • M De Deus Silva
  • I Diepholz
  • G Dixon
  • R Dolesi
  • L Ferraioli
  • V Ferroni
  • E D Fitzsimons
  • M Freschi
  • L Gesa
  • D Giardini
  • F Gibert
  • R Giusteri
  • C Grimani
  • J Grzymisch
  • I Harrison
  • M S Hartig
  • G Heinzel
  • M Hewitson
  • D Hollington
  • D Hoyland
  • M Hueller
  • H Inchauspé
  • O Jennrich
  • P Jetzer
  • N Karnesis
  • B Kaune
  • N Korsakova
  • C J Killow
  • L Liu
  • J A Lobo
  • J P López-Zaragoza
  • R Maarschalkerweerd
  • D Mance
  • V Martín
  • J Martino
  • L Martin-Polo
  • F Martin-Porqueras
  • P W McNamara
  • J Mendes
  • L Mendes
  • N Meshksar
  • M Nofrarias
  • S Paczkowski
  • M Perreur-Lloyd
  • A Petiteau
  • P Pivato
  • E Plagnol
  • J Ramos-Castro
  • J Reiche
  • F Rivas
  • D I Robertson
  • G Russano
  • L Sala
  • D Serrano
  • J Slutsky
  • C F Sopuerta
  • T Sumner
  • D Texier
  • J I Thorpe
  • D Vetrugno
  • S Vitale
  • G Wanner
  • H Ward
  • P Wass
  • W J Weber
  • L Wissel
  • A Wittchen
  • P Zweifel

Abstract

A precise characterization of the magnetic properties of LISA Pathfinder free falling test-masses is of special interest for future gravitational wave observatory in space. Magnetic forces have an important impact on the instrument sensitivity in the low frequency regime below the millihertz. In this paper we report on the magnetic injection experiments performed throughout LISA Pathfinder operations. We show how these experiments allowed a high precision estimate of the instrument magnetic parameters. The remanent magnetic moment was found to have a modulus of $(0.245\pm0.081)\,\rm{nAm}^2$, the x-component of the background magnetic field within the test masses position was measured to be $(414 \pm 74)$ nT and its gradient had a value of $(-7.4\pm 2.1)\,μ$T/m. Finally, we also measured the test mass magnetic susceptibility to be $(-3.35\pm0.15)\times$10$^{-5}$ in the low frequency regime. All results are in agreement with on-ground estimates.

Submitted

5 July 20241 year ago

Version

v1

License

CC-BY-4.0

DOI

10.48550/arXiv.2407.04431

Cite this preprint

Imports into BibLaTeX, Zotero, Mendeley, EndNote.

PDF

Open PDF

Opens in a new tab · v1.

Chat with this PDF

Ask questions, probe assumptions, request a plain-English summary. Answers cite sections from the preprint itself.

Community

Questions and answers about this paper from other readers. No formal peer review — just a place to think out loud.

Precision measurements of the magnetic parameters of LISA Pathfinder test masses · Antigravity