AG-2026.04-1436·gr-qc·cross-listed: astro-ph.HEastro-ph.IM
Gauge Theoretic Signal Processing II: Zero-Latency Whitening for Early Warning Pipelines
Authors
- James Kennington
- Joshua Black
- Zach Yarbrough
- Yun-Jing Huang
- Chad Hanna
- Leo Tsukada
- Amanda Baylor
- Olivia Godwin
- Prathamesh Joshi
- Cody Messick
- Surabhi Sachdev
- Ron Tapia
Abstract
Low-latency gravitational-wave search pipelines provide early-warning alerts for multimessenger astrophysical transients. Current pipelines whiten the data stream using acausal, linear-phase filters, which require a look-ahead buffer that introduces several seconds of algorithmic latency. Eliminating this latency requires causal, minimum-phase whitening filters using only past data. However, operating causal filters under non-stationary noise is non-trivial: the drifting power spectral density must be tracked without degrading the matched-filter signal-to-noise ratio (SNR), filter updates must preserve the minimum-phase condition, and the altered phase response must be compensated to maintain sky-localization accuracy. In Paper I we introduced a gauge theoretic signal processing framework and showed that the minimum-phase connection on the manifold of power spectra provides a geometrically exact update rule for causal filters. Here we validate that framework numerically and operationally, demonstrating that parallel transport along this connection strictly preserves the minimum-phase property while exactly conserving the matched-filter SNR. We numerically certify the flatness of this connection, showing that the optimal filter is a path-independent state function of the instantaneous noise. Through an injection campaign on O3 data with 15,347 binary black hole signals across the LIGO-Virgo network, we confirm that this architecture preserves the detection sensitivity and inter-detector timing and phase accuracy of the linear-phase baseline. Implementing the framework in the production sgnl pipeline reduces whitening latency by 1.0 s (33%) at a 4-second noise estimation cadence, confirmed in controlled tests and on live O3 replay data at production scale. Stride reduction experiments show that up to 91% of baseline trigger latency can be eliminated with sub-second pipeline cadence.
Submitted
28 April 2026yesterday
Version
v1
License
CC-BY-4.0
DOI
10.48550/arXiv.2604.25116
Chat with this PDF
Ask questions, probe assumptions, request a plain-English summary. Answers cite sections from the preprint itself.
Community
Questions and answers about this paper from other readers. No formal peer review — just a place to think out loud.