AG-2026.04-1572·astro-ph.HE·cross-listed: astro-ph.IM
SVOM/VT: Preliminary Calibration Analysis
Authors
- Zhu-Heng Yao
- Yu-Lei Qiu
- Jin-Song Deng
- Li-Ping Xin
- Chao Wu
- Hua-Li Li
- Jing Wang
- Yi-Nuo Ma
- Hong-Bo Cai
- Xu-Hui Han
- Jian-Yan Wei
- Betrand Cordier
Abstract
We present the in-orbit calibration of the Visible Telescope (VT), one of the key instruments aboard the Space Variable Objects Monitor (SVOM) mission for gamma-ray burst (GRB) studies. Using Gaia Data Release 3 (DR3) as a reference, the VT achieves an astrometric precision better than 0.03'' for bright stars, degrading to ~0.25'' for faint targets. Shortly after launch, contamination was detected, reducing system transmission by ~40%. An initial bake-out successfully restored performance, but gradual recontamination caused transmission to decline by ~20% over the following 100 days before stabilizing. Despite this effect, routine standard star observations maintain precise zero-point calibration, ensuring a photometric stability of 0.02 mag. Using synthetic stellar spectra, we derived photometric transformations to the Gaia, SDSS, and Johnson-Cousins systems with typical residuals of 0.03 mag. These results demonstrate the VT system's capability and reliability in calibrating GRBs and other transients.
Submitted
27 April 2026yesterday
Version
v1
License
CC-BY-4.0
DOI
10.48550/arXiv.2604.24256
Chat with this PDF
Ask questions, probe assumptions, request a plain-English summary. Answers cite sections from the preprint itself.
Community
Questions and answers about this paper from other readers. No formal peer review — just a place to think out loud.