AG-2026.04-2095·physics.optics
Leveraging natural fluctuations for matrix-based aberration correction in photoacoustic imaging
Authors
- Yevgeny Slobodkin
- Ori Katz
Abstract
Photoacoustic imaging is the leading technique for deep tissue optical imaging, allowing single-shot imaging at depths. However, its resolution may be limited by acoustic aberrations, caused by natural unknown heterogeneities in the tissue speed of sound. In recent years, reflection-matrix based scattering-compensation techniques have been successfully employed in ultrasound, optics, and seismology, to computationally correct such distortions. However, they have not been adapted to photoacoustic imaging since they rely on multiple acquisitions under different controlled excitations, such as input plane-wave illuminations, which do not result in signal changes in photoacoustics. Here, we introduce a framework that enables the direct application of the state-of-the-art reflection-matrix based aberration correction techniques to photoacoustic imaging of dynamic targets. Specifically, we show that a covariance matrix analysis of a conventional set of photoacoustic frames of dynamic targets, such as flowing red blood cells in blood vessels, yields a virtual reflection-matrix that is mathematically analogous to a pulse-echo reflection-matrix, and lends itself to direct processing by conventional reflection-matrix based scattering-compensation algorithms. We validate and demonstrate the approach for photoacoustic aberration correction of vessel-mimicking targets containing flowing absorbers in both simulations and experiments.
Submitted
30 April 20261 month ago
Version
v1
License
CC-BY-4.0
DOI
10.48550/arXiv.2604.27774
Summary
Researchers adapted reflection-matrix techniques—proven distortion-correctors in other imaging fields—to photoacoustic imaging by mining natural motion in tissue to create the mathematical structure these algorithms need.
- Photoacoustic imaging sees its resolution blurred by acoustic aberrations (variations in sound speed through tissue), but existing computational fixes require controlled light inputs that don't work in this context.
- The key insight: analyzing how image features naturally shift as blood cells flow creates a 'virtual' reflection matrix equivalent to what traditional scattering-correction algorithms expect, letting you reuse proven methods.
- This bridges a gap between two imaging worlds—the physics of photoacoustics finally gains access to sophisticated aberration-removal techniques that ultrasound and optics have been using for years.
curious · generated by claude-haiku-4-5
Chat with this PDF
Ask questions, probe assumptions, request a plain-English summary. Answers cite sections from the preprint itself.
Community
Questions and answers about this paper from other readers. No formal peer review — just a place to think out loud.