AG-2026.05-115·gr-qc
Impact of sky localization uncertainty on ringdown inference
Authors
- Kallol Dey
- Enrico Barausse
- Marco Crisostomi
- Roberto Trotta
Abstract
As gravitational-wave ringdown signals grow louder, quasinormal-mode inference depends increasingly on the treatment of extrinsic parameters. Standard analyses fix sky localization - and sometimes also polarization and inclination - to point estimates from a prior inspiral-merger-ringdown analysis, artificially breaking degeneracies and underestimating the true uncertainty of mode-amplitude values. We test two alternatives: uninformative priors on the extrinsic parameters, sampled jointly with the remnant mass, spin, mode amplitudes, and phases; and informed priors on sky position from the full signal posterior. The former yields wider marginal constraints on amplitude posteriors, and both avoid potential bias introduced by fixing the sky localization. In contrast, mode amplitude ratios remain consistent across approaches, making them a robust observable for Kerr spectroscopy. Our publicly available pipeline enables fast ringdown analyses capable of sampling all parameters, requiring tens of minutes on a laptop for a full inference. Applied to GW250114 and GW190521, our methods confirm the robust detection of the $(2,2,1)$ overtone in GW250114, and, for GW190521, find only mild evidence for the $(3,3,0)$ mode.
Submitted
18 May 20262 weeks ago
Version
v1
License
CC-BY-4.0
DOI
10.48550/arXiv.2605.18595
Summary
Ringdown inference with uninformative extrinsic-parameter priors or informed sky-position priors avoids bias from fixed localizations while keeping mode-amplitude ratios robust for Kerr spectroscopy.
- Fixing sky localization to inspiral-merger-ringdown point estimates artificially breaks degeneracies and underestimates amplitude uncertainty; joint sampling of extrinsic and intrinsic parameters yields wider, less biased marginal constraints.
- Mode-amplitude ratios remain consistent across prior choices (uninformative vs. informed extrinsic priors), establishing them as reliable Kerr-spectroscopy observables even when individual amplitudes are prior-dependent.
- A computationally efficient pipeline enables full-parameter ringdown analyses on standard hardware (tens of minutes per event), demonstrated on GW250114 (confirming (2,2,1) overtone) and GW190521 (weak (3,3,0) evidence).
specialist · generated by claude-haiku-4-5
Chat with this PDF
Ask questions, probe assumptions, request a plain-English summary. Answers cite sections from the preprint itself.
Community
Questions and answers about this paper from other readers. No formal peer review — just a place to think out loud.