physics.med-ph
AG-2025.03-1765
physics.med-ph
Zlatko Dimcovski, Michael Doser
Following a successful pioneering study of the biological effects of antimatter ( the AD-4/ACE experiment at CERN), the use of antiprotons in clinical radiotherapy became a very serious possibility. A major part of any future radiotherapy using antiprotons will be real-time imaging of antiproton annihilation in biological targets. In principle, real-time imaging is possible thanks to the secondary particles, neutral pions and charger pions, produced by the annihilation of antiprotons in the cells they come to a stop in.Neutral pions decay dominantly and almost instantaneously into a photon pair, and one approach to real-time imaging is based on the detection of these high-energy gammas. An alternative is based on the detection of charged pions, which have lifetimes almost a billion times longer than neutral pions. This paper is a brief review of this field of research, from the first real-time imaging achieved by the AD-4/ACE experiment in 2004 to the present day.
31 Mar 2025
AG-2024.05-1676
physics.med-ph
Ziyun Yu, Yijin Xie, Guodong Jin, Yunbin Zhu, Qi Zhang, Fazhan Shi, Fang-yan Wan, Hongmei Luo, Ai-hui Tang, Xing Rong
Magnetocardiography (MCG) has emerged as a sensitive and precise method to diagnose cardiovascular diseases, providing more diagnostic information than traditional technology. However, the sensor limitations of conventional MCG systems, such as large size and cryogenic requirement, have hindered the widespread application and in-depth understanding of this technology. In this study, we present a high-sensitivity, room-temperature MCG system based on the negatively charged Nitrogen-Vacancy (NV) centers in diamond. The magnetic cardiac signal of a living rat, characterized by an approximately 20 pT amplitude in the R-wave, is successfully captured through non-invasive measurement using this innovative solid-state spin sensor. To detect these extremely weak biomagnetic signals, we utilize sensitivity-enhancing techniques such as magnetic flux concentration. These approaches have enabled us to simultaneously achieve a magnetometry sensitivity of 9 $\text{pT}\cdot \text{Hz}^{-1/2}$ and a sensor scale of 5 $\text{mm}$. By extending the sensing scale of the NV centers from cellular and molecular level to macroscopic level of living creatures, we have opened the future of solid-state quantum sensing technologies in clinical environments.
3 May 2024
AG-2015.06-1384
physics.med-ph
Pol Grasland-Mongrain, Francois Destrempes, Jean-Martial Mari, Remi Souchon, Stefan Catheline, Jean-Yves Chapelon, Cyril Lafon, Guy Cloutier
Ultrasound speckle is a granular texture pattern appearing in ultrasound imaging. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasound-based medical imaging technique of the tissue electrical conductivity. It is based on the application of an ultrasound wave in a medium placed in a magnetic field and on the measurement of the induced electric current due to Lorentz force. Similarly to ultrasound imaging, we hypothesized that a speckle could be observed with Lorentz force electrical impedance tomography imaging. In this study, we first assessed the theoretical similarity between the measured signals in Lorentz force electrical impedance tomography and in ultrasound imaging modalities. We then compared experimentally the signal measured in both methods using an acoustic and electrical impedance interface. Finally, a bovine muscle sample was imaged using the two methods. Similar speckle patterns were observed. This indicates the existence of an "acousto-electrical speckle" in the Lorentz force electrical impedance tomography with spatial characteristics driven by the acoustic parameters but due to electrical impedance inhomogeneities instead of acoustic ones as is the case of ultrasound imaging.
18 Jun 2015
AG-2015.06-1366
physics.med-ph
Gregory T. Clement, Tomoo Kamakura
A tomographic method is considered that forms images from sets of spatially randomized source signals and receiver sensitivities. The method is designed to allow image reconstruction for an extended number of transmitters and receivers in the presence noise and without plane wave approximation or otherwise approximation on the size or regularity of source and receiver functions. An overdetermined set of functions are formed from the Hadamard product between a Gaussian function and a uniformly distributed random number set. It is shown that this particular type of randomization tends to produce well-conditioned matrices whose pseudoinverses may be determined without implementing relaxation methods. When the inverted sets are applied to simulated first-order scattering from a Shepp-Logan phantom, successful image reconstructions are achieved for signal-to-noise ratios (SNR) as low as 1. Evaluation of the randomization approach is conducted by comparing condition numbers with other forms of signal randomization. Image quality resulting from tomographic reconstructions is then compared with an idealized synthetic aperture approach, which is subjected to a comparable SNR. By root-mean-square-difference comparisons it is concluded that - provided a sufficient level of oversampling - the dynamic transmit and dynamic receive approach produces superior images, particularly in the presence of low SNR.
17 Jun 2015
AG-2015.06-1218
physics.med-ph
Yue Yan, Poonam Yadav, Michael Bassetti, Kaifang Du, Daniel Saenz, Paul Harari, Bhudatt R. Paliwal
Purpose: To quantitatively compare the dosimetric and biologic differences in treatment plans from flattened and flattening-filter-free (FFF) beam for three anatomic cancer sites. Methods and Materials: Treatment plans with static intensity-modulated radiotherapy beams and volumetric modulated arc therapy beams were generated for 13 patients for both the flattened beam and the FFF beam of the TrueBeam system. Beam energies of 6 MV and 10 MV were chosen for planning. A total of 104 treatment plans were generated in 13 patients. In order to analyze the biological effectiveness of treatment plans, dose volume histograms (DVH) were utilized. Flattened and FFF beam plans are quantitatively compared. Results: In head and neck cases, for VMAT plans, dose reduction in the FFF beam plans compared to the flattened beam in left cochlea, right submandibular gland and right parotid gland reached up to 2.36 Gy, 1.21 Gy and 1.45 Gy, respectively. Similarly, for static IMRT plans, the dose reduction of the FFF beam plans compared to the flattened beam plans for the same organs reached up to 0.34 Gy, 1.36 Gy and 1.46 Gy, respectively. Overall, for head and neck, the FFF beam plans achieved mean dose reduction of up to 5%, 7% and 9%, respectively for above organs at risk. For lung and prostate cases, the FFF beams provided lower or comparable NTCP values to organ-at-risk (OAR) compared to the flattened beam for all plans. Conclusions: In general, we observed treatment plans utilizing FFF beams can improve dose sparing to OARs without compromising the target coverage. Significant dose sparing effect is obtained for head and neck cancer cases, especially for the cases with relatively large field sizes (about 16x20 cm^2). For lung and prostate cases, compared to the flattened beam, the FFF beam based treatment plans provide lower or comparable dose to most OARs.
16 Jun 2015
AG-2015.06-1036
physics.med-ph
Christopher J. Bateman, Kishore Rajendran, Niels J. A. de Ruiter, Anthony P. Butler, Philip H. Butler, Peter F. Renaud
K-edge imaging is commonly used for viewing contrast pharmaceuticals in a variety of multi-energy x-ray imaging techniques, ranging from dual-energy and spectral computed tomography to fluoroscopy. When looking for the K-edge signal of a specific contrast, by taking measurements either side of the K-edge, it is found that the K-edge is not always observable for low concentrations. We have also observed that the ability to see the K-edge is unit dependent - a K-edge that is not observable in computed tomography (CT) reconstructed linear attenuation units can often be made visible by converting to Hounsfield units. This paper presents an investigation of this K-edge hiding phenomenon. We conclude that if a multi-energy x-ray measurement of any K-edge material contains a signal of any other material, then there will be a positive concentration of that K-edge material below which its K-edge cannot be observed without extracting the K-edge signal through means of basis decomposition. Mathematical descriptions of this limiting minimum concentration is provided in three cases - multi-energy radiographic projection images; and reconstructed multi-energy CT images for both linear attenuation and Hounsfield units. Two important properties of this limiting concentration are provided: the minimum concentration for Hounsfield units is always strictly less than the minimum concentration for linear attenuation; and the minimum concentration for radiographic projections will typically be much larger than the minimum concentration for reconstructed linear attenuation. Finally experimental observation of this phenomenon is presented using data collected by the MARS spectral CT scanner equipped with a CdTe Medipix-3RX camera operating in charge-summing mode, where it is also shown that the K-edge can be recovered through basis decomposition.
13 Jun 2015
AG-2015.06-1146
physics.med-ph
Olalekan A. Babaniyi, Assad A. Oberai, Paul E. Barbone
We consider the problem of estimating the $2D$ vector displacement field in a heterogeneous elastic solid deforming under plane stress conditions. The problem is motivated by applications in quasistatic elastography. From precise and accurate measurements of one component of the $2D$ vector displacement field and very limited information of the second component, the method reconstructs the second component quite accurately. No a priori knowledge of the heterogeneous distribution of material properties is required. This method relies on using a special form of the momentum equations to filter ultrasound displacement measurements to produce more precise estimates. We verify the method with applications to simulated displacement data. We validate the method with applications to displacement data measured from a tissue mimicking phantom, and in-vivo data; significant improvements are noticed in the filtered displacements recovered from all the tests. In verification studies, error in lateral displacement estimates decreased from about $50\%$ to about $2\%$, and strain error decreased from more than $250\%$ to below $2\%$.
11 Jun 2015
AG-2015.06-767
physics.med-ph
Jonathan Nemirovsky, Efrat Shimron
A method is presented for estimating unknown Fourier domain (k-space) data using a small number of samples in that space. The method is derived from Bochners Theorem, and is termed: Bochner Inequality Completion of K-Space (BICKS). It is suitable for filling the k-space of a real and nonnegative unknown quantity, and applicable even when the sampling rate is substantially lower than the Nyquist sampling rate. The BICKS method is demonstrated in the context of medical imaging, but it is also applicable to many other scientific areas that utilize signal processing in Fourier domain. The results indicate that filling a highly undersampled k-space using BICKS enables high quality image reconstruction.
10 Jun 2015
AG-2015.06-531
physics.med-ph
Samir Biswas, Peter van Es, Wiendelt Steenbergen, Srirang Manohar
Photoacoustic imaging of interphalangeal peripheral joints is of interest in the context of using the synovial membrane as a surrogate marker of rheumatoid arthritis. Previous work has shown that ultrasound produced by absorption of light at the epidermis reflects on the bone surfaces within the finger. When the reflected signals are backprojected in the region of interest, artifacts are produced, confounding interpretation of the images. In this work, we present an approach where the photoacoustic signals known to originate from the epidermis, are treated as virtual ultrasound transmitters, and a separate reconstruction is performed as in ultrasound reflection imaging. This allows us to identify the bone surfaces. Further, the identification of the joint space is important as this provides a landmark to localize a region-of-interest in seeking the inflamed synovial membrane. The ability to delineate bone surfaces allows us not only to identify the artifacts, but also to identify the interphalangeal joint space without recourse to new US hardware or a new measurement. We test the approach on phantoms and on a healthy human finger.
6 Jun 2015
AG-2015.05-2161
physics.med-ph
Kwangzoo Chung, Jinsung Kim, Dae-Hyun Kim, Sunghwan Ahn, Youngyih Han
To expedite the commissioning process of the proton therapy system at Samsung Medical Center (SMC), we have developed a Monte Carlo simulation model of the proton therapy nozzles using TOPAS. At SMC proton therapy center, we have two gantry rooms with different types of nozzles; a multi-purpose nozzle and a dedicated scanning nozzle. Each nozzle has been modeled in detail following the geometry information provided by the manufacturer, Sumitomo Heavy Industries, Ltd. For this purpose, novel features of TOPAS, such as the time feature or the ridge filter class, have been used. And the appropriate physics models for proton nozzle simulation were defined. Dosimetric properties, like percent depth dose curve, spread-out Bragg peak (SOBP), beam spot size, have been simulated and verified against measured beam data. Beyond the Monte Carlo nozzle modeling, we have developed an interface between TOPAS and the treatment planning system (TPS), RayStation. An exported RT plan data from the TPS has been interpreted by the interface and then translated into the TOPAS input text. The developed Monte Carlo nozzle model can be used to estimate non-beam performance of the nozzles such as the neutron background. Furthermore, the nozzle model can be used to study mechanical optimization in the design of the nozzle.
29 May 2015
AG-2015.05-2141
physics.med-ph
Bernard Gottschalk, Ethan W. Cascio, Juliane Daartz, Miles S. Wagner
The dose distribution of a pencil beam in water consists of a core, a halo, an aura and (possibly) spray. The core is due to primary protons which suffer multiple Coulomb scattering (MCS) and slow down by multiple collisions with atomic electrons (Bethe-Bloch theory). The halo is due to charged secondaries, many of them protons, from elastic interactions with H, elastic and inelastic interactions with O, and nonelastic interactions with O. We show that the halo radius is roughly one third of the beam range. The aura is due to neutral secondaries (neutrons and gamma rays). Spray denotes dose, avoidable in principle, coming in from the beam line. We have measured the absolute dose at 177 MeV using a test beam in a water tank. The beam monitor was a PPIC 'proton counter' and the field IC a dose calibrated Exradin T1. We took depth-dose scans at ten displacements from the beam axis ranging from 0 to 10 cm. The dose spans five orders of magnitude, and the transition from halo to aura is obvious. We present model-dependent (MD) and model-independent (MI) fits to these data. The MD fit has 25 parameters, and the goodness of fit (rms (measurement/fit) - 1) is 15%. The MI fit uses cubic spline fits in depth and radius. The goodness of fit is 9%. This fit is more portable and conceptually simpler. We discuss the prevalent parameterization of the core/halo originated by the PSI group. We argue that its use of T(w), a mass stopping power which includes energy deposited by nuclear secondaries, is incorrect. The electromagnetic (Bethe-Bloch) mass stopping power should be used instead. In consequence, 'Bragg peak chamber' measurements and associated corrections are, in our view, irrelevant. Furthermore, using T(w) leads to spurious excess dose on the axis of the core around midrange, which may be significant in fields involving relatively few pencil beams.
29 May 2015
AG-2015.05-1936
physics.med-ph
M. J. Malinowski, E. Matsinos, S. Roth
The present paper aims at providing the theoretical background required for investigating the use of the Microsoft Kinect$^{\rm TM}$ (`Kinect', for short) sensors (original and upgraded) in the analysis of human motion. Our methodology is developed in such a way that its application be easily adaptable to comparative studies of other systems used in capturing human-motion data. Our future plans include the application of this methodology to two situations: first, in a comparative study of the performance of the two Kinect sensors; second, in pursuing their validation on the basis of comparisons with a marker-based system (MBS). One important feature in our approach is the transformation of the MBS output into Kinect-output format, thus enabling the analysis of the measurements, obtained from different systems, with the same software application, i.e., the one we use in the analysis of Kinect-captured data; one example of such a transformation, for one popular marker-placement scheme (`Plug-in Gait'), is detailed. We propose that the similarity of the output, obtained from the different systems, be assessed on the basis of the comparison of a number of waveforms, representing the variation within the gait cycle of quantities which are commonly used in the modelling of the human motion. The data acquisition may involve commercially-available treadmills and a number of velocity settings: for instance, walking-motion data may be acquired at $5$ km/h, running-motion data at $8$ and $11$ km/h. We recommend that particular attention be called to systematic effects associated with the subject's knee and lower leg, as well as to the ability of the Kinect sensors in reliably capturing the details in the asymmetry of the motion for the left and right parts of the human body. The previous versions of the study have been withdrawn due to the use of a non-representative database.
27 May 2015
AG-2015.05-1223
physics.med-ph
Miguel Rodriguez, Josep Sempau, Antonella Fogliata, Luca Cozzi, Wolfgang Sauerwein, Lorenzo Brualla
Monte Carlo (MC) simulation of linacs depends on the accurate geometrical description of the head. The geometry of the Varian TrueBeam (TB) linac is not available to researchers. Instead, the company distributes phase-space files (PSFs) of the flattening-filter-free (FFF) beams tallied upstream the jaws. Yet, MC simulations based on third party tallied PSFs are subject to limitations. We present an experimentally-based geometry developed for the simulation of the FFF beams of the TB linac. The upper part of the TB linac was modeled modifying the Clinac 2100 geometry. The most important modification is the replacement of the standard flattening filters by ad hoc thin filters which were modeled by comparing dose measurements and simulations. The experimental dose profiles for the 6MV and 10MV FFF beams were obtained from the Varian Golden Data Set and from in-house measurements for radiation fields ranging from 3X3 to 40X40 cm2. Indicators of agreement between the experimental data and the simulation results obtained with the proposed geometrical model were the dose differences, the root-mean-square error and the gamma index. The same comparisons were done for dose profiles obtained from MC simulations using the second generation of PSFs distributed by Varian for the TB linac. Results of comparisons show a good agreement of the dose for the ansatz geometry similar to that obtained for the simulations with the TB PSFs for all fields considered, except for the 40X40 cm2 field where the ansatz geometry was able to reproduce the measured dose more accurately. Our approach makes possible to: (i) adapt the initial beam parameters to match measured dose profiles; (ii) reduce the statistical uncertainty to arbitrarily low values; and (iii) assess systematic uncertainties by employing different MC codes.
19 May 2015
AG-2015.05-1011
physics.med-ph
Adrian A. Sanchez
The goal of this thesis is to provide a framework for the use of task-based metrics of image quality to aid in the design, implementation, and evaluation of CT image reconstruction algorithms and CT systems in general. We support the view that task-based metrics of image quality can be useful in guiding the algorithm design and implementation process in order to yield images of objectively superior quality and higher utility for a given task. Further, we believe that metrics such as the Hotelling observer (HO) SNR can be used as summary scalar metrics of image quality for the evaluation of images produced by novel reconstruction algorithms. In this work, we aim to construct a concise and versatile formalism for image reconstruction algorithm design, implementation, and assessment. The bulk of the work focuses on linear analytical algorithms, specifically the ubiquitous filtered back-projection (FBP) algorithm. However, due to the demonstrated importance of optimization-based algorithms in a wide variety of CT applications, we devote one chapter to the characterization of noise properties in TV-based iterative reconstruction, as the understanding of image statistics in optimization-based reconstruction is the limiting factor in applying HO metrics.
14 May 2015
AG-2015.05-895
physics.med-ph
Hao Zhang, Jing Wang, Jianhua Ma, Hongbing Lu, Zhengrong Liang
Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose X-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method for various clinical tasks. According to the maximum a posterior (MAP) estimation, the SIR methods can be typically formulated by an objective function consisting of two terms: (1) data-fidelity (or equivalently, data-fitting or data-mismatch) term modeling the statistics of projection measurements, and (2) regularization (or equivalently, prior or penalty) term reflecting prior knowledge or expectation on the characteristics of the image to be reconstructed. Existing SIR methods for low-dose CT can be divided into two groups: (1) those that use calibrated transmitted photon counts (before log-transform) with penalized maximum likelihood (pML) criterion, and (2) those that use calibrated line-integrals (after log-transform) with penalized weighted least-squares (PWLS) criterion. Accurate statistical modeling of the projection measurements is a prerequisite for SIR, while the regularization term in the objective function also plays a critical role for successful image reconstruction. This paper reviews several statistical models on CT projection measurements and various regularization strategies incorporating prior knowledge or expected properties of the image to be reconstructed, which together formulate the objective function of the SIR methods for low-dose X-ray CT.
14 May 2015
AG-2015.05-776
physics.med-ph
Manuel Pinheiro, J. L. Alves
In this work it is proposed a medical image segmentation pipeline for accurate bone segmentation from CT imaging. It is a two-step methodology, with a pre-segmentation step and a segmentation refinement step. First, the user performs a rough segmenting of the desired region of interest. Next, a fully automatic refinement step is applied to the pre-segmented data. The automatic segmentation refinement is composed by several sub-stpng, namely image deconvolution, image cropping and interpolation. The user-defined pre-segmentation is then refined over the deconvolved, cropped, and up-sampled version of the image. The algorithm is applied in the segmentation of CT images of a composite femur bone, reconstructed with different reconstruction protocols. Segmentation outcomes are validated against a gold standard model obtained with coordinate measuring machine Nikon Metris LK V20 with a digital line scanner LC60-D that guarantees an accuracy of 28 $μm$. High sub-pixel accuracy models were obtained for all tested Datasets. The algorithm is able to produce high quality segmentation of the composite femur regardless of the surface meshing strategy used.
12 May 2015
AG-2015.05-148
physics.med-ph
Ignasi Méndez
The purpose of this study was to find the most accurate model for radiochromic film dosimetry by comparing different channel independent perturbation models. A model selection approach based on (algorithmic) information theory was followed, and the results were validated using gamma-index analysis on a set of benchmark test cases. Several questions were addressed: (a) whether incorporating the information of the non-irradiated film, by scanning prior to irradiation, improves the results; (b) whether lateral corrections are necessary when using multichannel models; (c) whether multichannel dosimetry produces better results than single-channel dosimetry; (d) which multichannel perturbation model provides more accurate film doses. It was found that scanning prior to irradiation and applying lateral corrections improved the accuracy of the results. For some perturbation models, increasing the number of color channels did not result in more accurate film doses. Employing Truncated Normal perturbations was found to provide better results than using Micke-Mayer perturbation models.} Among the models being compared, the triple-channel model with Truncated Normal perturbations, net optical density as the response and subject to the application of lateral corrections was found to be the most accurate model. The scope of this study was circumscribed by the limits under which the models were tested. In this study, the films were irradiated with megavoltage radiotherapy beams, with doses from about 20 cGy to 600 cGy, entire (8 ${\rm inch}$ $\times$ 10 ${\rm inch}$) films were scanned, the functional form of the sensitometric curves was a polynomial and the different lots were calibrated using the plane-based method.
4 May 2015
AG-2015.05-131
physics.med-ph
M. J. Malinowski, E. Matsinos
The present study is part of a broader programme, exploring the possibility of involving the Microsoft Kinect$^{\rm TM}$ sensor in the analysis of human motion. We examine the output obtained from the two available versions of this sensor in relation to the variability of the estimates of the lengths of eight bones belonging to the subject's extremities: of the humerus (upper arm), ulna (lower arm, forearm), femur (upper leg), and tibia (lower leg, shank). Large systematic effects in the output of the two sensors have been observed.
2 May 2015
AG-2015.04-1690
physics.med-ph
Sajib Saha, Rajib Rana, Ya. I. Nesterets, M. Tahtali, Frank de Hoog, T. E. Gureyev
Source localization in EEG represents a high dimensional inverse problem, which is severely ill-posed by nature. Fortunately, sparsity constraints have come into rescue as it helps solving the ill-posed problems when the signal is sparse. When the signal has a structure such as block structure, consideration of block sparsity produces better results. Knowing sparse Bayesian learning is an important member in the family of sparse recovery, and a superior choice when the projection matrix is highly coherent (which is typical the case for EEG), in this work we evaluate the performance of block sparse Bayesian learning (BSBL) method for EEG source localization. It is already accepted by the EEG community that a group of dipoles rather than a single dipole are activated during brain activities; thus, block structure is a reasonable choice for EEG. In this work we use two definitions of blocks: Brodmann areas and automated anatomical labelling (AAL), and analyze the reconstruction performance of BSBL methodology for them. A realistic head model is used for the experiment, which was obtained from segmentation of MRI images. When the number of simultaneously active blocks is 2, the BSBL produces overall localization accuracy of less than 5 mm without the presence of noise. The presence of more than 3 simultaneously active blocks and noise significantly affect the localization performance. Consideration of AAL based blocks results more accurate source localization in comparison to Brodmann area based blocks.
27 Apr 2015
AG-2015.04-1682
physics.med-ph
Artur Słomski, Zbigniew Rudy, Tomasz Bednarski, Piotr Białas, Eryk Czerwiński, Łukasz Kapłon, Andrzej Kochanowski, Grzegorz Korcyl, Jakub Kowal, Paweł Kowalski, Tomasz Kozik, Wojciech Krzemień, Marcin Molenda, Paweł Moskal, Szymon Niedźwiecki, Marek Pałka, Monika Pawlik, Lech Raczyński, Piotr Salabura, Neha Gupta-Sharma, Michał Silarski, Jerzy Smyrski, Adam Strzelecki, Wojciech Wiślicki, Marcin Zieliński, Natalia Zoń
Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines connecting two detectors. As there is a multitude of detectors build-in typical PET tomograph structure, there are many possible detector pairs that pertain to the measurement. The problem is how to turn this measurement into an image (this is called imaging). Decisive improvement in PET image quality was reached with the introduction of iterative reconstruction techniques. This stage was reached already twenty years ago (with the advent of new powerful computing processors). However, three dimensional (3D) imaging remains still a challenge. The purpose of the image reconstruction algorithm is to process this imperfect count data for a large number (many millions) of lines-of-responce (LOR) and millions of detected photons to produce an image showing the distribution of the labeled molecules in space.
26 Apr 2015
AG-2015.04-1541
physics.med-ph
Yan Xi, Rongbiao Tang, Jingchen Ma, Jun Zhao
We propose a one-shot thickness measurement method for sponge-like structures using a propagation-based X-ray phase-contrast imaging (P-PCI) method. In P-PCI, the air-material interface refracts the incident X-ray. Refracted many times along their paths by such a structure, incident X-rays propagate randomly within a small divergent angle range, resulting in a speckle pattern in the captured image. We found structure thickness and contrast of a phase-contrast projection are directly related in images. This relationship can be described by a natural logarithm equation. Thus, from the one phase-contrast view, depth information can be retrieved from its contrast. Our preliminary biological experiments indicate promise in its application to measurements requiring in vivo and ongoing assessment of lung tumor progression.
24 Apr 2015
AG-2015.04-1571
physics.med-ph
Thomas Bortfeld, Jagdish Ramakrishnan, John N. Tsitsiklis, Jan Unkelbach
We analyze the effect of tumor repopulation on optimal dose delivery in radiation therapy. We are primarily motivated by accelerated tumor repopulation towards the end of radiation treatment, which is believed to play a role in treatment failure for some tumor sites. A dynamic programming framework is developed to determine an optimal fractionation scheme based on a model of cell kill due to radiation and tumor growth in between treatment days. We find that faster tumor growth suggests shorter overall treatment duration. In addition, the presence of accelerated repopulation suggests larger dose fractions later in the treatment to compensate for the increased tumor proliferation. We prove that the optimal dose fractions are increasing over time. Numerical simulations indicate potential for improvement in treatment effectiveness.
24 Apr 2015
AG-2015.04-1305
physics.med-ph
Saeed Ranjbar
Recently, the ventricular torsional parameters have received special attention because of their significant role in the ventricular systolic and diastolic function. Right ventricular (RV) rotational deformation is a sensitive index for RV performance but difficult to measure. Having assumed RV as a conic shape, the present study serves a novel mathematical formula of right ventricular rotation that uses velocity vector imaging (VVI) for quantifying RV.
21 Apr 2015
AG-2015.04-998
physics.med-ph
Bernard L. Jones, Tracey Schefter, Moyed Miften
Recent studies suggest that 4DCT is unable to accurately measure respiratory-induced pancreatic tumor motion. In this work, we assessed the daily motion of pancreatic tumors treated with SBRT, and developed adaptive strategies to predict and account for this motion. The daily motion trajectory of pancreatic tumors during CBCT acquisition was calculated using a model which reconstructs the instantaneous 3D position in each 2D CBCT projection image. We developed a metric (termed "Spectral Coherence," SC) based on the Fourier frequency spectrum of motion in the SI direction, and analyzed the ability of SC to predict motion-based errors and classify patients according to motion characteristics. The amplitude of daily motion exceeded the predictions of pre-treatment 4DCT imaging by an average of 3.0 mm, 2.3 mm, and 3.5 mm in the AP, LR, and SI directions. SC was correlated with daily motion differences and tumor dose coverage. In a simulated adaptive protocol, target margins were adjusted based on SC, resulting in significant increases in mean target D95, D99, and minimum dose. Our Fourier-based approach differentiates between consistent and inconsistent motion characteristics of respiration and correlates with daily motion deviations from pre-treatment 4DCT. The feasibility of an SC-based adaptive protocol was demonstrated, and this patient-specific respiratory information was used to improve target dosimetry by expanding coverage in inconsistent breathers while shrinking treatment volumes in consistent breathers.
16 Apr 2015
AG-2015.04-722
physics.med-ph
Yuan Jie Cao, Suk Lee, Kyung Hwan Chang, Jang Bo Shim, Kwang Hyeon Kim, Min Sun Jang, Won Sup Yoon, Dae Sik Yang, Young Je Park, Chul Yong Kim
To compare the dosimetrical differences between plans generated by helical tomotherapy using 2D or 3D margining technique in in prostate cancer. Ten prostate cancer patients were included in this study. For 2D plans, planning target volume (PTV) was created by adding 5 mm (lateral/anterior-posterior) to clinical target volume (CTV). For 3D plans, 5 mm margin was added not only in lateral/anterior-posterior, but also in superior-inferior to CTV. Various dosimetrical indices, including the prescription isodose to target volume (PITV) ratio, conformity index (CI), homogeneity index (HI), target coverage index (TCI), modified dose homogeneity index (MHI), conformation number (CN), critical organ scoring index (COSI), and quality factor (QF) were determined to compare the different treatment plans. Differences between 2D and 3D PTV indices were not significant except for CI (p = 0.023). 3D margin plans (11195 MUs) resulted in higher (13.0%) monitor units than 2D margin plans (9728 MUs). There were no significant differences in any OARs between the 2D and 3D plans. Overall, the average 2D plan dose was slightly lower than the 3D plan dose. Compared to the 2D plan, the 3D plan increased average treatment time by 1.5 minutes; however, this difference was not statistically significant (p = 0.082). We confirmed that 2D and 3D margin plans are not significantly different with regard to various dosimetric indices such as PITV, CI, and HI for PTV, and OARs with tomotherapy.
13 Apr 2015
AG-2015.04-030
physics.med-ph
M. J. Malinowski, E. Matsinos
The present paper is part of a broader programme, exploring the possibility of involving the Microsoft Kinect$^{\rm TM}$ sensor in the analysis of human motion. In this study, the output obtained from the two available versions of this sensor is critically examined. We demonstrate that the two outputs differ in regard to the variation of the physical quantities involved in the modelling of the human motion. As the original sensor has been found unsuitable for applications requiring high precision, the observed differences in the output of the two sensors call for the validation of the upgraded sensor on the basis of a marker-based system.
1 Apr 2015
AG-2015.03-1619
physics.med-ph
T. E. Gureyev, Ya. I. Nesterets
We describe the relationship between different forms of linearized expressions for the spatial distribution of intensity of X-ray projection images obtained in the Fresnel region. We prove that under the natural validity conditions some of the previously published expressions can be simplified without a loss of accuracy. We also introduce modified validity conditions which are likely to be fulfilled in many relevant practical cases, and which lead to a further significant simplification of the expression for the image-plane intensity, permitting simple non-iterative linear algorithms for the phase retrieval.
24 Mar 2015
AG-2015.03-1541
physics.med-ph
Hidetake Hara, Hiroshi Muraishi, Hiroki Matsuzawa, Toshiyuki Inoue, Shinji Abe, Hitoshi Satoh, Yasuo Nakajima
We have recently developed a phantom that simulates acute ischemic stroke. We attempted to visualize acute-stage cerebral infarction by applying virtual monochromatic images to this phantom using dual-energy CT (DECT). Virtual monochromatic images were created using DECT from 40 to 100 keV at every 10 keV and from 60 to 80 keV at every 1 keV, under three energy conditions of tube voltages with thin (Sn) filters. Calculation of the CNR values allowed us to evaluate the visualization of acute-stage cerebral infarction. The CNR value of a virtual monochromatic image was the highest at 68 keV under 80 kV / Sn 140 kV, at 72 keV under 100 kV / Sn 140 kV, and at 67 keV under 140 kV / 80 kV. The CNR values of virtual monochromatic images between 65 and 75 keV were significantly higher than those obtained for all other created energy images. Therefore, optimal conditions for visualizing acute ischemic stroke were achievable.
23 Mar 2015
AG-2015.03-1163
physics.med-ph
Kwangwoo Park, Wonhoon Choi, Sungho Park, Jin Hwa Choi, Suk Won Park, Jino Bak
We studied the investigation of volume averaging effect for air-filled cylindrical ionization chambers to determine correction factors in small photon field for the given chamber. As a method, we measured output factors using several cylindrical ionization chambers and calculated with mathematical method similar to deconvolution in which we modeled non-constant and inhomogeneous exposure function in the cavity of chamber. The parameters in exposure function and correction factors were determined by solving a system of equations we developed with measurement data and geometry of the given chamber. Correction factors (CFs) we had found are very similar to that from Monte Carlo (MC) simulation. For example, CFs in this study were computed as 1.116 for PTW31010, and 1.0225 for PTW31016, while CFs from MC were reported as approximately between 1.17 and 1.20 for PTW31010, and between 1.02 and 1.06 for PTW31016 in of 6MV photon beam . Furthermore, the result from the method of deconvolution combined with MC for chamber response function, also showed similar CF for PTW 30013, which was reported as 2.29 and 1.54 in and filed size respectively. The CFs from our method provided similarly as 2.42 and 1.54. In addition, we reported CFs for PTW30013, PTW31010, PTW31016, IBA FC23-C, and IBA CC13. As a consequence, we suggested a newly developed method to measure correct output factor using the fact that inhomogeneous exposure, force a volume averaging effect in a cavity of air filled cylindrical ionization chamber. The result from this method is very similar to that from MC simulation. The method we developed can easily be applied to clinic.
17 Mar 2015
AG-2015.03-1168
physics.med-ph
JeongOk Lee, JeongKu Kang, JhinKee Kim, HyeongCheol Kwon, JungSoo Kim, BuGil Kim, DongHyeok Jeong
The use of GEANT4 code has increased in the medical field. There are various studies to calculate the patient dose distributions with the GEANT4 code using the imaging data. In present study, the Monte Carlo simulations based on the DICOM data were performed to calculate absorbed dose in the patient's body. Various visualization tools were equipped in the GEANT4 code to display the detector construction, however there are limitations to display the DICOM images. In addition, it is difficult to display the dose distributions on the imaging data of the patient. Recently, gMocren code, volume visualization tool for GEANT4 simulation, has been developed and used in volume visualization of image files. In this study, the imaging data based absorbed dose distributions in patient were performed by using the gMocren code. The dosimetric evaluations with TLD and film dosimetry methods were carried out to verify the calculation results.
17 Mar 2015
AG-2015.03-1068
physics.med-ph
Matteo Anselmino, Stefania Scarsoglio, Carlo Camporeale, Andrea Saglietto, Fiorenzo Gaita, Luca Ridolfi
Background. Despite the routine prescription of rate control therapy for atrial fibrillation (AF), clinical evidence demonstrating a heart rate target is lacking. Aim of the present study was to run a mathematical model simulating AF episodes with a different heart rate (HR) to predict hemodynamic parameters for each situation. Methods. The lumped model, representing the pumping heart together with systemic and pulmonary circuits, was run to simulate AF with HR of 50, 70, 90, 110 and 130 bpm, respectively. Results. Left ventricular pressure increased by 56.7%, from 33.92+-37.56 mmHg to 53.15+-47.56 mmHg, and mean systemic arterial pressure increased by 27.4%, from 82.66+-14.04 mmHg to 105.29+-7.63 mmHg, at the 50 and 130 bpm simulations, respectively. Stroke volume (from 77.45+-8.5 to 39.09+-8.08 mL), ejection fraction (from 61.1+-4.4 to 39.32+-5.42%) and stroke work (SW, from 0.88+-0.04 to 0.58+-0.09 J) decreased by 49.5, 35.6 and 34.2%, at the 50 and 130 bpm simulations, respectively. In addition, oxygen consumption indexes (rate pressure product, RPP, tension time index per minute, TTI/min, and pressure volume area per minute, PVA/min) increased from the 50 to the 130 bpm simulation, respectively, by 185.7% (from 5598+-1939 to 15995+-3219 mmHg/min), 55.5% (from 2094+-265 to 3257+-301 mmHg s/min) and 102.4% (from 57.99+-17.9 to 117.37+-25.96 J/min). In fact, left ventricular efficiency (SW/PVA) decreased from 80.91+-2.91% at 50 bpm to 66.43+-3.72% at the 130 bpm HR simulation. Conclusion. Awaiting compulsory direct clinical evidences, the present mathematical model suggests that lower HRs during permanent AF relates to improved hemodynamic parameters, cardiac efficiency, and lower oxygen consumption.
16 Mar 2015
AG-2015.03-1052
physics.med-ph
Bram L. Gorissen, Aswin L. Hoffmann
Comparison of optimization algorithms for inverse treatment planning requires objective function value evaluation.
16 Mar 2015
AG-2015.03-885
physics.med-ph
Kwang-Ho Cheong, Me-Yeon Lee, Sei-Kwon Kang, Jai-Woong Yoon, Soah Park, Taejin Hwang, Haeyoung Kim, Kyoung Ju Kim, Tae Jin Han, Hoonsik Bae
The aim of this study is to set up statistical quality control for monitoring of volumetric modulated arc therapy (VMAT) delivery error using machine log data. Eclipse and Clinac iX linac with the RapidArc system (Varian Medical Systems, Palo Alto, USA) is used for delivery of the VMAT plan. During the delivery of the RapidArc fields, the machine determines the delivered motor units (MUs) and gantry angle position accuracy and the standard deviations of MU (sigma_MU; dosimetric error) and gantry angle (sigma_GA; geometric error) are displayed on the console monitor after completion of the RapidArc delivery. In the present study, first, the log data was analyzed to confirm its validity and usability; then, statistical process control (SPC) was applied to monitor the sigma_MU and sigma_GA in a timely manner for all RapidArc fields: a total of 195 arc fields for 99 patients. The sigma_MU and sigma_GA were determined twice for all fields, that is, first during the patient-specific plan QA and then again during the first treatment. The sigma_MU and sigma_GA time series were quite stable irrespective of the treatment site; however, the sigma_GA was strongly dependent on the gantry rotation speed. The sigma_GA of the RapidArc delivery for stereotactic body radiation therapy (SBRT) was smaller than that for the typical VMAT. Therefore, SPC was applied for SBRT cases and general cases respectively. Moreover, the accuracy of the potential meter of gantry rotation is important, since the sigma_GA can be dramatically changed due to its condition. By applying SPC to the sigma_MU and sigma_GA, we could monitor the delivery error efficiently. However, the upper and lower limits of SPC need to be determined carefully with full knowledge of the machine and log data.
13 Mar 2015
AG-2015.03-884
physics.med-ph
Jong Geun Baek, Hyun Soo Jang, Young Kee Oh, Hyun Jeong Lee, Eng Chan Kim
The purpose of this study was to evaluate the setup uncertainties for single-fraction stereotactic radiosurgery (SF-SRS) based on the clinical data with the two different mask-creation methods using pretreatment CBCT imaging guidance. Dedicated frameless fixation BrainLAB masks for 23 patients were created as a routine mask (R-mask) making method, as explained in the BrainLAB user manual. The alternative masks (A-mask) which were created by modifying the cover range of the R-mask for the patient head were used for 23 patients. The systematic errors including the each mask and stereotactic target localizer were analyzed and the errors were calculated as the mean and standard deviation (SD) from the LR, SI, AP, and yaw setup corrections. In addition, the frequency of three-dimensional (3D) vector length were also analyzed. The values of the mean setup corrections for the R-mask in all directions were small; < 0.7 mm and < 0.1 degree, whereas the magnitudes of the SDs were relatively large compared to the mean values. In contrast to the R-mask, the means and SDs of the A-mask were smaller than those for the R-mask with the exception of the SD in the AP direction. The mean and SD in the yaw rotational direction in the R-mask and A-mask system were comparable. The 3D vector shifts of a larger magnitude occurred more frequently for the R-mask than the A-mask. The setup uncertainties for each mask with the stereotactic localizing system had an asymmetric offset towards the positive AP direction. The A-mask-creation method, which is capable of covering the top of the patient head is superior to that for R-mask, and thereby the use of the A-mask is encouraged for SF-SRS to reduce the setup uncertainties. Moreover, the careful mask making is required to prevent the possible setup uncertainties.
13 Mar 2015
AG-2015.03-886
physics.med-ph
Jae Ik Shin, Ilsung Cho, Sungho Cho, Eun Ho Kim, Yongkeun Song, Won-Gyun Jung, SeungHoon Yoo, Dongho Shin, Se Byeong Lee, Myonggeun Yoon, Sebastian Incerti, Moshi Geso, Anatoly B. Rosenfeld
The aim of this study is to investigate the dose-deposition enhancement by alpha-particle irradiation in a cellular model using carbon and oxygen chemical compositions.A simulation study was performed to study dose enhancement due to carbon and oxygen for a human cell where Geant4 code used for the alpha-particle irradiation to the cellular phantom. The characteristic of dose enhancement in the nucleus and cytoplasm by the alpha-particle radiation was investigated based on concentrations of the carbon and oxygen compositions and was compared with those by gold and gadolinium.The results show that both the carbon and oxygen-induced dose enhancement was found to be more effective than those of gold and gadolinium. We found that the dose-enhancement effect was more dominant in the nucleus than in the cytoplasm if carbon or oxygen is uniformly distributed in a whole cell. In the condition that the added chemical composition was inserted only into the cytoplasm, the effect of the dose enhancement in nucleus becomes weak.We showed that high-stopping-power materials offer a more effective dose-enhancement efficacy and suggest that the carbon nanotubes and oxygenation are promising candidates for dose utilization as dose enhancement tools in particle therapy.
13 Mar 2015
AG-2015.03-883
physics.med-ph
Byung Jun Min, Heerim Nam, Il Sun Jeong, Hyebin Lee
In recent years, the use of PACS for radiation therapy has become the norm in hospital environment and has suggested for collecting data and management from different TPSs with DICOM objects. However, some TPS does not provide the DVH exportation with text or other format. In addition, plan review systems for various TPSs often allow DVH recalculation with different algorithms. These algorithms result in the inevitable discrepancy between the values obtained with the recalculation and those obtained with TPS itself. The purpose of this study was to develop a simple method for generating reproducible DVH values obtained from the TPSs. Treatment planning information including structures and delivered dose was exported by the DICOM format from planning systems. The supersampling and trilinear interpolation methods were employed to calculate DVH data from 35 treatment plans. The discrepancies between DVHs extracted from each TPS and the proposed calculation method were evaluated with respect to the supersampling ratio. The volume, minimum dose, maximum dose, and mean dose were compared. The variation of DVHs from multiple TPSs was compared with a commercially available treatment planning comparison tool. The overall comparisons of the volume, minimum dose, maximum dose, and mean dose showed that the proposed method generated relatively smaller discrepancies compared with TPS than those by MIM software and TPS. As the structure volume decreased, the overall percent difference increased. Most large difference was observed in the small organs such as eye ball, lens, optic nerve which had below 10 cc volume. A simple and useful technique was developed to generate DVH with acceptable error from a proprietary TPS. This study provides the convenient and common framework which allows to use a single well-managed storage solution for the independent information system.
13 Mar 2015
AG-2015.03-796
physics.med-ph
Yong Ho Kim, Ha Ryung Park, Won Taek Kim, Dong Won Kim, Yongkan Ki, Juhye Lee, Jinsuk Bae, Dahl Park
Collimator angle is usually rotated when planning volumetric modulated arc therapy (VMAT) due to the leakage of radiation between multi-leaf collimator (MLC) leaves. We studied the effect of the collimator angles on the results of dosimetric verification of the VMAT plans for head and neck patients. We studied VMAT plans for 10 head and neck patients. We made 2 sets of VMAT plans for each patient. Each set was composed of 10 plans with collimator angles of 0, 5, 10, 15, 20, 25, 30, 35, 40, 45 degrees. Plans in the first set were optimized individually and plans in the second set shared the 30 degree collimator angle optimization. Two sets of plans were verified using the 2-dimensional ion chamber array MatriXX (IBA Dosimetry, Germany). The comparison between the calculation and measurements were made by the $γ$-index analysis. The $γ$-index (2\%/2 mm) and (3\%/3 mm) passing rates had negative correlations with the collimator angle. Maximum difference between $γ$-index (3\%/3 mm) passing rates of different collimator angles for each patient ranged from 1.46\% to 5.60\% with an average of 3.67\%. There were significant differences (maximum 5.6\%) in the passing rates of different collimator angles. The results suggested that the accuracy of the delivered dose depends on the collimator angle. These findings are informative when choosing a collimator angle in VMAT plans.
12 Mar 2015
AG-2015.03-795
physics.med-ph
Dong Joo Rhee, Sung-woo Kim, Young Min Moon, Jung Ki Kim, Dong Hyeok Jeong
Computed Tomography (CT) measures the attenuation coefficient of an object and converts the value assigned to each voxel into a CT number. In radiation therapy, CT number, which is directly proportional to the linear attenuation coefficient, is required to be converted to electron density for radiation dose calculation for cancer treatment. However, if various tube voltages were applied to take the patient CT image without applying the specific CT number to electron density conversion curve, the accuracy of dose calculation would be unassured. In this study, changes in CT numbers for different materials due to change in tube voltage were demonstrated and the dose calculation errors in percentage depth dose (PDD) and a clinical case were analyzed. The maximum dose difference in PDD from TPS dose calculation and Monte Carlo simulation were 1.3 % and 1.1 % respectively when applying the same CT number to electron density conversion curve to the 80 kVp and 140 kVp images. In the clinical case, the different CT number to electron density conversion curves from 80 kVp and 140 kVp were applied to the same image and the maximum differences in mean, maximum, and minimum doses were 1.1 %, 1.2 %, 1.0 % respectively at the central region of the phantom and 0.6 %, 0.9 %, 0.8 % respectively at the peripheral region of the phantom.
12 Mar 2015
AG-2015.03-793
physics.med-ph
Suk Lee, Yuan Jie Cao, Kyung Hwan Chang, Jang Bo Shim, Kwang Hyeon Kim, Nam Kwon Lee, Young Je Park, Chul Yong Kim, Sam Ju Cho, Sang Hoon Lee, Chul Kee Min, Woo Chul Kim, Kwang Hwan Cho, Hyun Do Huh, Sangwook Lim, Dongho Shin
The purpose of this study was to use various dosimetrical indices to determine the best IMRT modality technique for treating patients with prostate cancer. Ten patients with prostate cancer were included in this study. Intensity modulated radiation therapy plans were designed to include different modalities, including the linac step and shoot, Tomotherapy, RapidArc, and Proton systems. Various dosimetrical indices, like the prescription isodose to target volume (PITV) ratio, conformity index (CI), homogeneity index (HI), target coverage index (TCI), modified dose homogeneity index (MHI), conformation number (CN), critical organ scoring index (COSI), and quality factor (QF) were determined to compare the different treatment plans. Biological indices such as the generalized equivalent uniform dose (gEUD), based tumor control probability (TCP), and normal tissue complication probability (NTCP) were also calculated and used to compare the treatment plans. The RapidArc plan attained better PTV coverage, as evidenced by its superior PITV, CI, TCI, MHI, and CN values. Regarding OARs, proton therapy exhibited superior dose sparing for the rectum and bowel in low dose volumes, whereas the Tomotherapy and RapidArc plans achieved better dose sparing in high dose volumes. The QF scores showed no significant difference among these plans (p=0.701). The average TCPs for prostate tumors in the RapidArc, Linac, and Proton plans were higher than the average TCP for Tomotherapy (98.79%, 98.76%, and 98.75% vs. 98.70%, respectively). Regarding the rectum NTCP, RapidArc showed the most favorable result (0.09%), whereas Linac resulted in the best bladder NTCP (0.08%).
12 Mar 2015
AG-2015.03-873
physics.med-ph
Soah Park, Kwang-Ho Cheong, Taejin Hwang, Jai-Woong Yoon, Taejin Han, Haeyoung Kim, Me-Yeon Lee, KyoungJu Kim, Hoonsik Bae, Sei-Kwon Kang
It is important to study absorption spectrum in film dosimetry because the spectral absorbance of the film relates to the film's total absorption dose. We investigated the absorption spectra of Gafchromic EBT2 film with various rotational angles in a visible wavelength band. The film was irradiated with 6 MV photon beams and a total dose of 300 cGy. Absorption spectra were taken under different rotational angles after 24 h after irradiation and we fitted the spectra using Lorentzian functions. There were two dominant absorption peaks at approximately 586 nm (green) and 634 nm (red). The measured spectrum was decomposed 542 nm, 558 nm, 578 nm, 586 nm, 626 nm, 634 nm, and 641 nm. The maximum total area of the red band absorption spectrum was at 45°(225°) and the minimum at 90°(270°). As the angle of rotation changed, the intensity and integrated area of the blue and green peaks also changed with 180° period, with minima at 90° and 270°, and maxima at 0° and 180°, although the overall absorbance is very low. The spectral peak wavelengths remained constant within 2.4 nm for all angles. There was no hysteresis of absorption spectrum of the film; spectra taken at 0° and 360°were substantially the same and showed similar behavior for all rotational angles. The change of absorbance with rotational angle of the film affected the dosimetric properties, resulting in rotationalvariations of film dosimetry in each red-green-blue channel.
12 Mar 2015
AG-2015.03-2220
physics.med-ph
Luciano Pandola, Claudio Andenna, Barbara Caccia
The bremsstrahlung spectra produced by electrons impinging on thick targets are simulated using the Geant4 Monte Carlo toolkit. Simulations are validated against experimental data available in literature for a range of energy between 0.5 and 2.8 MeV for Al and Fe targets and for a value of energy of 70keV for Al, Ag, W and Pb targets. All three independent sets of electromagnetic models available in Geant4 to simulate bremsstrahlung are tested. A quantitative analysis is performed reproducing with each model the energy spectrum for the different configurations of emission angles, energies and targets. At higher energies (0.5-2.8 MeV) of the impinging electrons on Al and Fe targets, Geant4 is able to reproduce the spectral shapes and the integral photon emission in the forward direction. The agreement is within 10-30%, depending on energy, emission angle and target material. The physics model based on the Penelope Monte Carlo code is in slightly better agreement with the measured data than the other two. However, all models over-estimate the photon emission in the backward hemisphere. For the lower energy study (70 keV), which includes higher-Z targets, all models systematically under-estimate the total photon yield, while still providing a reasonable agreement between 10 and 50%. The results of this work are of potential interest for medical physics applications, where knowledge of the energy spectra and angular distributions of photons is needed for accurate dose calculations with Monte Carlo and other fluence-based methods.
12 Mar 2015
AG-2015.03-804
physics.med-ph
Su Chul Han, Sang Hyun Choi, Seungwoo Park, Soon Sung Lee, Haijo Jung, Mi-Sook Kim, Hyung Jun Yoo, Young Hoon Ji, Chul Young Yi, Kum Bae Kim
The accuracy of deformable image registration (DIR) has a significant dosimetric impact in radiation treatment planning. We evaluated accuracy of various DIR algorithms using variations of the deformation point and volume. The reference image (Iref) and volume (Vref) was first generated with virtual deformation QA software (ImSimQA, Oncology System Limited, UK). We deformed Iref with axial movement of deformation point and Vref depending on the types of deformation that are the deformation1 is to increase the Vref (relaxation) and the deformation 2 is to decrease . The deformed image (Idef) and volume (Vdef) acquired by ImSimQA software were inversely deformed to Iref and Vref using DIR algorithms. As a result, we acquired deformed image (Iid) from Idef and volume (Vid) from Vdef. The DIR algorithms were the Horn Schunk optical flow (HS), Iterative Optical Flow (IOF), Modified Demons (MD) and Fast Demons (FD) with the Deformable Image Registration and Adaptive Radiotherapy Toolkit (DIRART) of MATLAB. The image similarity between Iref and Iid was calculated using the metrics that were Normalized Mutual Information (NMI) and Normalized Cross Correlation (NCC). When moving distance of deformation point was 4 mm, the value of NMI was above 1.81 and NCC was above 0.99 in all DIR algorithms.When the Vref increased or decreased about 12%, the difference between Vref and Vid was within 5% regardless of the type of deformation.The value of Dice Similarity Coefficient (DSC) was above 0.95 in deformation1 except for the MD algorithm. In case of deformation 2, that of DSC was above 0.95 in all DIR algorithms. The Idef and Vdef have not been completely restored to Iref and Vref and the accuracy of DIR algorithms was different depending on the degree of deformation. Hence, the performance of DIR algorithms should be verified for the desired applications.
12 Mar 2015
AG-2015.03-790
physics.med-ph
Joong Hyun Kim, Mikiko Ito, Soo Mee Kim, Seong Jong Hong, Jae Sung Lee
The aim of this study was to optimize the design of a monolithic LGSO scintillation crystal and micro parallel-hole collimator for the development of a small-animal single photon emission computed tomography (SPECT) system with compact size, low-cost and reasonable performance through Monte Carlo simulation. L0.9GSO crystals with surface area of 50 mm X 50 mm were investigated for the design optimization. The intrinsic detection efficiency, intrinsic spatial resolution, and intrinsic energy resolution of crystals were estimated for different crystal thicknesses and photon energies (using I-125 and Tc-99m sources). Two kinds of surface treatments (providing polished and rough surfaces) were compared by optical photon simulation. The standard deviation of the angle between a micro-facet and the mean surface was set to 0.1 and 6.0 for polished and rough surfaces, respectively. For comparison, the intrinsic performance of NaI(Tl) was also investigated. A multi-photomultiplier tube was designed with 16 X 16 anode pixels having size of 2.8 mm X 2.8 mm and pitch of 3.04 mm, and a 1.5 mm thickness glass window. The length of the micro collimator was also optimized. Finally, the performance of the SPECT system was assessed and an ultra-micro hot spot phantom image was obtained in simulation. The 1-mm-thick LGSO was sufficient to detect most incident photons from I-125 but a thickness of 3 mm was required for Tc-99m imaging. Polished crystal yielded better intrinsic spatial resolution (~540 μm) and lower light output than rough crystal. Energy resolutions of I-125 and Tc-99m were ~36.9% and ~19.1%. With the optimized collimator length, spatial resolution of ~1 mm and sensitivity of ~100 cps/MBq were achieved with a four-head SPECT system. A hot rod with a diameter of 1.0 mm was resolved in the SPECT image of ultra-micro hot spot phantom.
12 Mar 2015
AG-2015.03-789
physics.med-ph
Hyun Jeong Lee, Ji Woon Yea, Se An Oh
Respiratory-gated radiation therapy (RGRT) has been used to minimize the dose to normal tissue in lung-cancer radiotherapy. The present research aims to improve the regularity of respiration in RGRT using a video coached respiration guiding system. In the study, 16 patients with lung cancer were evaluated. The respiration signals of the patients were measured by a real-time position management (RPM) Respiratory Gating System (Varian, USA) and the patients were trained using the video coached respiration guiding system. The patients performed free breathing and guided breathing, and the respiratory cycles were acquired for ~5 min. Then, Microsoft Excel 2010 software was used to calculate the mean and standard deviation for each phase. The standard deviation was computed in order to analyze the improvement in the respiratory regularity with respect to the period and displacement. The standard deviation of the guided breathing decreased to 65.14% in the inhale peak and 71.04% in the exhale peak compared with the values for the free breathing of patient 6. It was found that the standard deviation of the respiratory cycle was decreased using the respiratory guiding system. 2 The respiratory regularity was significantly improved using the video coached respiration guiding system. Therefore, the system is useful for improving the accuracy and efficiency of RGRT.
12 Mar 2015
AG-2015.03-815
physics.med-ph
Youl-Hun Seoung
The purpose of the present study was to evaluate radiation dose reduction and image quality during CT scanning by using a new dose reduction fiber sheet (DRFS) with commercially available bismuth shields. These DRFS were composed of nano-barium sulfate (BaSO4), filling the gaps left by the large oxide bismuth (Bi2O3) particle sizes. The radiation dose was measured five times at directionss of 12 o'clock from the center of the polymethyl methacrylate (PMMA) head phantom to calculate an average value using a CT ionization chamber. The image quality measured CT transverse images of the PMMA head phantom depending on X-ray tube voltages and the type of shielding. Two regions of interest in CT transverse images were chosen from the right and left areas under the surface of the PMMA head phantom and from ion chamber holes located at directions of 12 o'clock from the center of the PMMA head phantom. The results of this study showed that the new DRFS shields could reduce dosages to 15.61%, 23.05%, and 22.71% more in 90 kVp, 120 kVp, and 140 kVp, respectively, than with a conventional bismuth shield of the same thickness, while maintaining image quality. In addition, the DRFS were produced to about 25% more thinness than conventional bismuth. We concluded, therefore, that DRFS can replace the conventional bismuth and may be utilized as a new shield.
12 Mar 2015
AG-2015.03-774
physics.med-ph
Wook-Geun Shin, Chul Hee Min, Jae-Ik Shin, Jong Hwi Jeong, Se Byeong Lee
For the in vivo range verification in proton therapy, it has been tried to measure the spatial distribution of the prompt gammas generated by the proton-induced interactions with the close relationship with the proton dose distribution. However, the high energy of the prompt gammas and background gammas are still problematic in measuring the distribution. In this study, we suggested a new method determining the in vivo range by utilizing the time structure of the prompt gammas formed with the rotation of a range modulation wheel (RMW) in the passive scattering proton therapy. To validate the Monte Carlo code simulating the proton beam nozzle, axial percent depth doses (PDDs) were compared with the measured PDDs with the varying beam range of 4.73-24.01 cm. And the relationship between the proton dose rate and the time structure of the prompt gammas was assessed and compared in the water phantom. The results of the PDD showed accurate agreement within the relative errors of 1.1% in the distal range and 2.9% in the modulation width. Average dose difference in the modulation was assessed as less than 1.3% by comparing with the measurement. The time structure of prompt gammas was well-matched within 0.39 ms with the proton dose rate, and this could enable the accurate prediction of the in vivo range.
12 Mar 2015
AG-2015.03-799
physics.med-ph
Sukyoung Shin, Soonhyouk Lee
Thermo plastic polyurethane (TPU) provides excellent bio-compatibility, flexibility and good irradiation resistance; however, extremely high irradiation doses can alter the structure and function of macromolecules, resulting in oxidation, chain scission and cross-linking. In this study, the effects of e-beam irradiation on the medical grade thermo plastic polyurethane were studied. The changes in the chain length and their distribution as well as the changes in molecular structure were studied. The GPC (Gel Permeation Chromatography) results show that the oxidative decomposition is followed by a decrease in molecular mass together with an increase in polydispersity. This indicates a very inhomogeneous degradation, which is a consequence of the specific course and of the intensity of oxidative degradation. This was confirmed by means of mechanical property measurements. Overall, this study demonstrated that the medical grade TPU was affected by radiation exposure, particularly at high irradiation doses.
12 Mar 2015
AG-2015.03-720
physics.med-ph
Young Eun Choi, Jungwon Kwak, Si Yeol Song, Eun Kyung Choi, Seung Do Ahn, Byungchul Cho
We compared the treatment planning performance of RapidArc (RA) vs. CyberKnife (CK) for spinal stereotactic body radiation therapy (SBRT). Ten patients with spinal lesions who had been treated with CK were re-planned with RA, which consisted of two complete arcs. Computed tomography (CT) and volumetric dose data of CK, generated using the Multiplan (Accuray) treatment planning system (TPS) and the Ray-Trace algorithm, were imported to Varian Eclipse TPS in Dicom format, and the data were compared with the RA plan using analytical anisotropic algorithm (AAA) dose calculation. The optimized dose priorities for both CK and RA plans were similar for all patients. The highest priority was to provide enough dose coverage to the planned target volume (PTV) while limiting the maximum dose to the spinal cord. Plan quality was evaluated with respect to PTV coverage, conformity index (CI), high-dose spillage, intermediate-dose spillage (R50% and D2cm), and maximum dose to the spinal cord, which are criteria recommended by RTOG 0631 spine and 0915 lung SBRT protocols. The mean CI +/- SD values of PTV were 1.11 +/- 0.03 and 1.17 +/- 0.10 for RA and CK (p = 0.02), respectively. On average, the maximum dose delivered to the spinal cord in CK plans was approximately 11.6% higher than in RA plans, and this difference was statistically significant (p < 0.001). High-dose spillages were 0.86% and 2.26% for RA and CK (p = 0.203), respectively. Intermediate-dose spillage characterized by D2cm was lower for RA than for CK; however, R50% was not statistically different. Even though both systems can create highly conformal volumetric dose distributions, the current study shows that RA demonstrates lower high- and intermediate-dose spillage than CK. Therefore, RA plans for spinal SBRT may be superior to CK.
11 Mar 2015
AG-2015.03-711
physics.med-ph
Hyunho Lee, Seonghoon Jeong, Yunhui Jo, Myonggeun Yoon
Quality assurance (QA) for medical linear accelerators is indispensable for appropriate cancer treatment. Some international organizations and western advanced countries provide QA guidelines for linear accelerators. Currently, QA regulations for linear accelerators in Korean hospitals specify a system in which each hospital stipulates its independent hospital-based protocols for QA procedures (HP_QAPs) and conducts QA based on these HP_QAPs while regulatory authorities verify whether items under these HP_QAPs have been performed. However, because this regulatory method cannot guarantee the quality of universal treatment, and QA items with tolerance criteria are different in many hospitals, the presentation of standardized QA items and tolerance criteria is essential. In this study, QA items in HP_QAPs from various hospitals and those presented by international organizations. Concordance rates between QA items for linear accelerators that were presented by the aforementioned organizations and those currently being implemented in Korean hospitals were shown to exhibit a daily QA of 50%, a weekly QA of 22%, a monthly QA of 43%, and an annual QA of 65%, and the overall concordance rates of all QA items were approximately 48%. In comparison between QA items being implemented in Korean hospitals and those being implemented in western advanced countries, concordance rates were shown to exhibit a daily QA of 50%, a weekly QA of 33%, a monthly QA of 60%, and an annual QA of 67%, and the overall concordance rate of all QA items were approximately 57%. The results of this study indicate that the HP_QAPs currently implemented by Korean hospitals as QA standards for linear accelerators used in radiation therapy do not meet international standards. To solve this problem, it is necessary to develop national standardized QA items and procedures for linear accelerators.
11 Mar 2015
AG-2015.03-722
physics.med-ph
KyoungJun Yoon, JungWon Kwak, DoHeui Lee, ByungChul Cho, SangWook Lee, SeungDo Ahn
The purpose of our study is to develop a new, 3-dimensional dosimetry system to verify the accuracy of dose deliveries in Leksell Gamma Knife-Perfexion TM (LGKP) (Elekta, Norcross, GA, USA). The instrument consists of a moving head phantom, an embedded thin active layer and a CCD camera system and was designed to be mounted to LGKP. As an active material concentrically located in the hemispheric head phantom, we choose Gafchromic EBT3 films and Gd2O2S;Tb phosphor sheets for dosimetric measurements. Also, to compensate the lack of backscatter, we located a 1 cm thick PMMA plate downstream of the active layer. The PMMA plate was transparent for scintillation lights to reach the CCD with 1200x1200 pixels by a 5.2 um pitch. Using this system, three hundred images by a 0.2 mm slice gap were acquired under each of three collimator setups, i.e. 4 mm, 8 mm, and 16 mm, respectively. The 2D projected images taken by CCD camera were compared with the dose distributions measured by EBT3 films in the same conditions. All 2D distributions were normalized by the maximum values derived by fitting peaks for each collimator setup. The FWHM differences of 2D profiles between of CCD images and of film doses were measured to be less than 0.3 mm. The scanning task for whole peak regions took less than three minutes with the new instrument. It could be utilized as a QA tool for the Gamma Knife radiosurgery system instead of film dosimetry, the use of which requires much more time and resources.
11 Mar 2015
AG-2015.03-715
physics.med-ph
Sung Jin Kim, Dong Ho Kim, Sung Kyu Kim
Treatment planning system calculations in inhomogeneous regions may present significant inaccuracies due to loss of electronic equilibrium. In this study, three different dose calculation algorithms, pencil beam, collapsed cone, and Monte-Carlo, provided by our planning system were compared to assess their impact on the three-dimensional planning of lung and breast cases. A total of five breast and five lung cases were calculated using the PB, CC, and MC algorithms. Planning treatment volume and organs at risk delineation was performed according to our institutions protocols on the Oncentra MasterPlan image registration module, on 0.3 to 0.5 cm computed tomography slices taken under normal respiration conditions. Four intensity-modulated radiation therapy plans were calculated according to each algorithm for each patient. The plans were conducted on the Oncentra MasterPlan and CMS Monaco treatment planning systems, for 6 MV. The plans were compared in terms of the dose distribution in target, OAR volumes, and monitor units. Furthermore, absolute dosimetry was measured using a three-dimensional diode array detector to evaluate the dose differences in a homogeneous phantom. Comparing the PB, CC, and MC algorithms planned dose distribution, the PB algorithm provided adequate coverage of the PTV. The MUs calculated using the PB algorithm was less than those of the other algorithms. The MC algorithm showed the highest accuracy in terms of the absolute dosimetry. Differences were found when comparing the calculation algorithms. The PB algorithm estimated higher doses for the target than the CC and MC algorithms. The PB algorithm actually overestimated the dose compared with those calculated by the CC and MC algorithms. The MC algorithm showed better accuracy than the other algorithms.
11 Mar 2015
AG-2015.03-785
physics.med-ph
Jin Sung Kim, Jung Suk Shin, Daehyun Kim, EunHyuk Shin, Kwangzoo Chung, Sungkoo Cho, Sung Hwan Ahn, Sanggyu Ju, Yoonsun Chung, Sang Hoon Jung, Youngyih Han
Two full rotating gantry with different nozzles (Multipurpose nozzle with MLC, Scanning Dedicated nozzle) with conventional cyclotron system is installed and under commissioning for various proton treatment options at Samsung Medical Center in Korea. The purpose of this study is to investigate neutron dose equivalent per therapeutic dose, H/D, to x-ray imaging equipment under various treatment conditions with monte carlo simulation. At first, we investigated H/D with the various modifications of the beam line devices (Scattering, Scanning, Multi-leaf collimator, Aperture, Compensator) at isocenter, 20, 40, 60 cm distance from isocenter and compared with other research groups. Next, we investigated the neutron dose at x-ray equipments used for real time imaging with various treatment conditions. Our investigation showed the 0.07 ~ 0.19 mSv/Gy at x-ray imaging equipments according to various treatment options and intestingly 50% neutron dose reduction effect of flat panel detector was observed due to multi- leaf collimator during proton scanning treatment with multipurpose nozzle. In future studies, we plan to investigate experimental measurement of neutron dose and validation of simulation data for x-ray imaging equipment with additional neutron dose reduction method.
11 Mar 2015
AG-2015.03-714
physics.med-ph
Young Kyu Lee, Hong Seok Jang, Yeon Sil Kim, Byung Ock Choi, Sang Hee Nam, Hyeong Wook Park, Shin Wook Kim, Hun Joo Shin, Jae Choon Lee, Ji Na Kim, Sung Kwang Park, Jin Young Kim, Young-Nam Kang
The purpose of this study is to evaluate the clinical usefulness of modulated arc (mARC) treatment techniques. The mARC treatment plans of the non-small cell lung cancer (NSCLC) patients were performed in order to verify the clinical usefulness of mARC. A pre study was conducted to find the most competent plan condition of mARC treatment and the usefulness of mARC treatment plan was evaluated by comparing it with the other Arc treatment plans such as Tomotherapy and RapidArc. In the case of mARC, the optimal condition for the mARC plan was determined by comparing the dosimetric performance of the mARC plans with the use of various parameters. The various parameters includes the photon energies (6 MV, 10 MV), optimization point angle (6°-10° intervals), and total segment number (36-59 segment). The best dosimetric performance of mARC was observed at 10 MV photon energy and the point angle 6 degree, and 59 segments. The each treatment plans of three different techniques were compared with the following parameters: conformity index (CI), homogeneity index (HI), target coverage, dose in the OARs, monitor units (MU), beam on time and the normal tissue complication probability (NTCP). As a result, all three different treatment techniques show the similar target coverage. The mARC results the lowest V20 and MU per fraction compared with both RapidArc and Tomotherapy plan. The mARC plan reduces the beam on time as well. Therefore, the results of this study provided a satisfactory result which mARC technique is considered as a useful clinical technique for radiation treatment.
11 Mar 2015
AG-2015.03-713
physics.med-ph
Hun-Joo Shin, Shin-Wook Kim, Chul Seung Kay, Jae-Hyuk Seo, Gi-Woong Lee, Ki-Mun Kang, Hong Seok Jang, Young-nam Kang
Purpose: 4D CBCT is a beneficial tool for the treatment of movable tumors, because it can help us to understand where the tumors are actually located and have a precise treatment plan. However, there is a limitation that general CBCT images cannot perfectly help the sophisticated registration. On the other hand, SymmetryTM 4D IGRT system of Elekta can offer the 4D CBCT registration option. In this study, we intend to evaluate the usefulness of SymmetryTM. Method and Materials: Planning CT images of the CIRS moving lung phantom were acquired from 4D MDCT. And they are sorted as 10 phases from 0% phase to 90% phase. The thickness of CT images was 1 mm. Acquired MDCT images were transferred to the contouring software and a virtual target was generated. An one arc VMAT plan was performed by using the treatment planning system on the virtual target. Finally, the movement of the phantom was verified through XVI SymmetryTM system. Results: The physical movement of CIRS moving lung phantom was +/- 10.0 mm in superior-inferior direction, +/- 1.0 mm in lateral direction, and +/- 2.5 mm in anterior-posterior direction. The movement of the phantom was measured from 4D MDCT registration as +/- 10.2 mm in superior-inferior direction, +/- 0.9 mm in lateral direction, and +/- 2.45 mm in anterior-posterior direction. The movement of the phantom was measured from SymmetryTM registration as +/- 10.1 mm in superior-inferior direction, +/- 0.9 mm in lateral direction, and +/- 2.4 mm in anterior/posterior direction. Conclusion: It is confirmed that 4D CBCT is a beneficial tool for the treatment of movable tumors. Therefore, 4D registration of SymmetryTM can increase the precision of the registration when a movable tumor is a target of radiation treatment.
11 Mar 2015
AG-2015.03-716
physics.med-ph
Byung Yong Kim, Hyung Dong Kim, Dong Ho Kim, Jong Geun Baek, Su Ho Moon, Gwang Won Rho, Jeong Ku Kang, Sung Kyu Kim
Most virtual source models (VSM) use beam modeling, with the exception of the patient-dependent secondary collimator (jaw). Unlike other components of the treatment head, the jaw absorbs many photons generated by the bremsstrahlung, which decreases the efficiency of the simulation. In the present study, a new method of beam modeling using a virtual jaw was applied to improve the calculation efficiency of VSM. The results for the percentage depth dose and profile of the virtual jaw VSM calculated in a homogeneous water phantom agreed with the measurement results for the CC13 cylinder type ion chamber within an error rate of 2%, and the 80 to 20% penumbra width agreed with the measurement results within an error of 0.6 mm. Compared with the existing VSM, in which a great number of photons are absorbed, the calculation efficiency of the VSM using the virtual jaw was expected to increase by approximately 67%.
11 Mar 2015
AG-2015.03-614
physics.med-ph
Seonghoon Jeong, Myonggeun yoon, Weon Kuu Chung, Dong Wook Kim
In these days, 3D-printer is on the rise in various fields including radiation therapy. This preliminary study aimed to estimate the dose characteristics of the 3D-printer materials which could be used as the compensator or immobilizer in radiation treatment. The cubes which have 5cm length and different densities as 50%, 75% and 100% were printed by 3D-printer. A planning CT scans for cubes were performed using a CT simulator (Brilliance CT, Philips Medical System, Netherlands). Dose distributions behind the cube were calculated when 6MV photon beam passed through cube. The dose response for 3D-printed cube, air and water were measured by using EBT3 film and 2D array detector. When results of air case were normalized to 100, dose calculated by TPS and measured dose of 50% and 75% cube were 96~99. Measured and calculated doses of water and 100% cube were 82~84. HU values of 50%, 75% and 100% were -910, -860 and -10, respectively. From these results, 3D-printer in radiotherapy could be used for medical purpose accurately.
10 Mar 2015
AG-2015.03-616
physics.med-ph
Jihye Koo, Myonggeun Yoon, Weon Kuu Chung, Dong Wook Kim
This study estimated the planning quality of intensity-modulated radiotherapy in 42 lung cancer cases to provide preliminary data for the development of a planning quality assurance algorithm. Organs in or near the thoracic cavity (ipsilateral lung, contralateral lung, heart, liver, esophagus, spinal cord, and bronchus) were selected as organs at risk (OARs). Radiotherapy plans were compared using the conformity index (CI), coverage index (CVI), and homogeneity index (HI) of the planning target volume (PTV), OAR-PTV distance and OAR-PTV overlap volume, and the V10Gy, V20Gy, and equivalent uniform dose (EUD) of the OARs. The CI, CVI, and HI of the PTV were 0.54 - 0.89 , 0.90 - 1.00 , and 0.11 - 0.41, respectively. The mean EUDs (V10Gy, V20Gy) of the ipsilateral lung, contralateral lung, esophagus, cord, liver, heart, and bronchus were 8.07 Gy (28.06, 13.17), 2.59 Gy (6.53, 1.18), 7.02 Gy (26.17, 12.32), 3.56 Gy (13.56, 4.48), 0.72 Gy (2.15, 0.91), 5.14 Gy (19.68, 8.62), and 10.56 Gy (36.08, 19.79), respectively. EUDs tended to decrease as OAR-PTV distance increased and OAR-PTV overlap volume decreased. Because the plans in this study were from a single department, relatively few people were involved in treatment planning. Differences in treatment results for a given patient would be much more pronounced if many departments were involved.
10 Mar 2015
AG-2015.03-618
physics.med-ph
Yongkeun Song, Jaeik Shin, Sungho Cho, Seunghoon Yoo, Ilsung Cho, Eunho Kim, Sanghyoun Choi, Kyungmin Oh, Wongyun Jung
We investigated the parameter optimization of ridge filter thickness using a Monte Carlo simulation for carbon ion therapy. For this study, a ridge filter was designed for the Spread-Out Bragg Peak (SOBP) by considering the relative biological effect (RBE). The thickness, height, and width of the ridge filter were designed by using the FLUKA and GEANT4 code, and we analyzed and compared the results of the physical dose distribution for the FLUKA and GEANT4 coding. The results show that the minimum width of the groove for the ridge filter should be at least 0.4cm for the appropriate biological dose. The SOBP sections are 8cm, 9cm, and 10cm, respectively, when heights are 3.5cm, 4.0cm, and 4.5cm. The height of the ridge filter is designed to be associated with the SOBP width. Also, the results for the FLUKA and GEANT4 code show that an average value of difference is 3% and a maximum error is 5%; however, its trend was similar. Therefore, the height and width of the groove for the ridge filter are used for important parameters to decide the length and plateau of SOBP.
10 Mar 2015
AG-2015.03-349
physics.med-ph
Zhen Tian, Yongbao Li, Michael Folkerts, Feng Shi, Steve B. Jiang, Xun Jia
Monte Carlo (MC) simulation is considered as the most accurate method for radiation dose calculations. Accuracy of a source model for a linear accelerator is critical for the overall dose calculation accuracy. In this paper, we presented an analytical source model that we recently developed for GPU-based MC dose calculations. A key concept called phase-space-ring (PSR) was proposed. It contained a group of particles that are of the same type and close in energy and radial distance to the center of the phase-space plane. The model parameterized probability densities of particle location, direction and energy for each primary photon PSR, scattered photon PSR and electron PSR. For a primary photon PSRs, the particle direction is assumed to be from the beam spot. A finite spot size is modeled with a 2D Gaussian distribution. For a scattered photon PSR, multiple Gaussian components were used to model the particle direction. The direction distribution of an electron PSRs was also modeled as a 2D Gaussian distribution with a large standard deviation. We also developed a method to analyze a phase-space file and derive corresponding model parameters. To test the accuracy of our linac source model, dose distributions of different open fields in a water phantom were calculated using our source model and compared to those directly calculated using the reference phase-space file. The average distance-to-agreement (DTA) was within 1 mm for the depth dose in the build-up region and beam penumbra regions. The root-mean-square (RMS) dose difference was within 1.1% for dose profiles at inner and outer beam regions. The maximal relative difference of output factors was within 0.5%. Good agreements were also found in an IMRT prostate patient case and an IMRT head-and-neck case. These results demonstrated the efficacy of our source model in terms of accurately representing a reference phase-space file.
5 Mar 2015
AG-2015.03-350
physics.med-ph
Zhen Tian, Michael Folkerts, Yongbao Li, Feng Shi, Steve B. Jiang, Xun Jia
We recently built an analytical source model for GPU-based MC dose engine. In this paper, we present a sampling strategy to efficiently utilize this source model in GPU-based dose calculation. Our source model was based on a concept of phase-space-ring (PSR). This ring structure makes it effective to account for beam rotational symmetry, but not suitable for dose calculations due to rectangular jaw settings. Hence, we first convert PSR source model to its phase-space let (PSL) representation. Then in dose calculation, different types of sub-sources were separately sampled. Source sampling and particle transport were iterated. So that the particles being sampled and transported simultaneously are of same type and close in energy to alleviate GPU thread divergence. We also present an automatic commissioning approach to adjust the model for a good representation of a clinical linear accelerator . Weighting factors were introduced to adjust relative weights of PSRs, determined by solving a quadratic minimization problem with a non-negativity constraint. We tested the efficiency gain of our model over a previous source model using PSL files. The efficiency was improved by 1.70 ~ 4.41, due to the avoidance of long data reading and transferring. The commissioning problem can be solved in ~20 sec. Its efficacy was tested by comparing the doses computed using the commissioned model and the uncommissioned one, with measurements in different open fields in a water phantom under a clinical Varian Truebeam 6MV beam. For the depth dose curves, the average distance-to-agreement was improved from 0.04~0.28 cm to 0.04~0.12 cm for build-up region and the root-mean-square (RMS) dose difference after build-up region was reduced from 0.32%~0.67% to 0.21%~0.48%. For lateral dose profiles, RMS difference was reduced from 0.31%~2.0% to 0.06%~0.78% at inner beam and from 0.20%~1.25% to 0.10%~0.51% at outer beam.
5 Mar 2015
AG-2015.02-1994
physics.med-ph
Wei Zhao, Kai Niu, Sebastian Schafer, Kevin Royalty
The characteristics of an x-ray spectrum can greatly influence imaging and related tasks. In practice, due to the pile-up effect of the detector, it's difficult to directly measure the spectrum of a CT scanner using an energy resolved detector. An alternative solution is to estimate the spectrum using transmission measurements with a step phantom or other CT phantom. In this work, we present a new spectrum estimation method based on indirect transmission measurement and model spectra mixture approach. The estimated x-ray spectrum was expressed as weighted summation of a set of model spectra, which can significantly reduce the degrees of freedom (DOF) of the spectrum estimation problem. Next, an estimated projection can be calculated with the assumed spectrum. By iteratively updating the unknown weights, we minimized the difference between the estimated projection data and the raw projection data. The final spectrum was calculated with these calibrated weights and the model spectra. Both simulation and experimental data were used to evaluate the proposed method. In the simulation study, the estimated spectra were compared to the raw spectra which were used to generate the raw projection data. For the experimental study, the ground truth measurement of the raw x-ray spectrum was not available. Therefore, the estimated spectrum was compared against spectra generated using the SpekCalc software with tube configurations provided by the scanner manufacturer. The results show the proposed method has potential to accurately estimate x-ray spectra using the raw projection data. The difference between the mean energy of the raw spectra and the mean energy of the estimated spectra were smaller than 0.5 keV for both simulation and experimental data. Further tests show the method was robust with respect to the model spectra generator.
28 Feb 2015
AG-2015.02-1816
physics.med-ph
John-John Cabibihan, Deepak Joshi, Yeshwin Mysore Srinivasa, Mark Aaron Chan, Arrchana Muruganantham
To touch and be touched are vital to human development, well being, and relationships. However, to those who have lost their arms and hands due to accident or war, touching becomes a serious concern that often leads to psychosocial issues and social stigma. In this paper, we demonstrate that the touch from a warm and soft rubber hand can be perceived by another person as if the touch were coming from a human hand. We describe a three step process toward this goal. First, we made participants select artificial skin samples according to their preferred warmth and softness characteristics. At room temperature, the preferred warmth was found to be 28.4 deg C at the skin surface of a soft silicone rubber material that has a Shore durometer value of 30 at the OO scale. Second, we developed a process to create a rubber hand replica of a human hand. To compare the skin softness of a human hand and artificial hands, a robotic indenter was employed to produce a softness map by recording the displacement data when constant indentation force of 1 N was applied to 780 data points on the palmar side of the hand. Results showed that an artificial hand with skeletal structure is as soft as a human hand. Lastly, the participants arms were touched with human and artificial hands, but they were prevented to see the hand that touched them. Receiver operating characteristic curve analysis suggests that a warm and soft artificial hand can create an illusion that the touch is from a human hand. These findings open the possibilities for prosthetic and robotic hands that are lifelike and are more socially acceptable.
27 Feb 2015
AG-2015.02-1626
physics.med-ph
Alice P. Bates, Zubair Khalid, Rodney A. Kennedy
We propose a sampling scheme on the sphere and develop a corresponding spherical harmonic transform (SHT) for the accurate reconstruction of the diffusion signal in diffusion magnetic resonance imaging (dMRI). By exploiting the antipodal symmetry, we design a sampling scheme that requires the optimal number of samples on the sphere, equal to the degrees of freedom required to represent the antipodally symmetric band-limited diffusion signal in the spectral (spherical harmonic) domain. Compared with existing sampling schemes on the sphere that allow for the accurate reconstruction of the diffusion signal, the proposed sampling scheme reduces the number of samples required by a factor of two or more. We analyse the numerical accuracy of the proposed SHT and show through experiments that the proposed sampling allows for the accurate and rotationally invariant computation of the SHT to near machine precision accuracy.
25 Feb 2015
AG-2015.02-1076
physics.med-ph
Ivan I. Maximov, Farida Grinberg, Irene Neuner, N. Jon Shah
Clinical diffusion imaging requires short acquisition times and good image quality to permit its use in various medical applications. In turn, these demands require the development of a robust and efficient post-processing framework in order to guarantee useful and reliable results. However, multiple artefacts abound in in vivo measurements; from either subject such as cardiac pulsation, bulk head motion, respiratory motion and involuntary tics and tremor, or imaging hardware related problems, such as table vibrations, etc. These artefacts can severely degrade the resulting images and render diffusion analysis difficult or impossible. In order to overcome these problems, we developed a robust and efficient framework enabling the use of initially corrupted images from a clinical study. At the heart of this framework is an improved least trimmed squares diffusion tensor estimation algorithm that works well with severely degraded datasets with low signal-to-noise ratio. This approach has been compared with other diffusion imaging post-processing algorithms using simulations and in vivo experiments. Exploiting track-based spatial statistics analysis, we demonstrate that corrupted datasets can be restored and reused in further clinical studies rather than being discarded due to poor quality. The developed robust framework is shown to exhibit a high efficiency and accuracy and can, in principle, be exploited in other MR studies where artefact/outlier suppression is needed.
17 Feb 2015
AG-2015.02-1041
physics.med-ph
Benjamin Mauroy, Patrice Flaud, Dominique Pelca, Christian Fausser, Jacques Merckx, Barrett R. Mitchell
Chest physiotherapy is an empirical technique used to help secretions to get out of the lung whenever stagnation occurs. Although commonly used, little is known about the inner mechanisms of chest physiotherapy and controversies about its use are coming out regularly. Thus, a scientific validation of chest physiotherapy is needed to evaluate its effects on secretions. We setup a quasi-static numerical model of chest physiotherapy based on thorax and lung physiology and on their respective biophysics. We modeled the lung with an idealized deformable symmetric bifurcating tree. Bronchi and their inner fluids mechanics are assumed axisymmetric. Static data from the literature is used to build a model for the lung's mechanics. Secretions motion is the consequence of the shear constraints apply by the air flow. The input of the model is the pressure on the chest wall at each time, and the output is the bronchi geometry and air and secretions properties. In the limit of our model, we mimicked manual and mechanical chest physiotherapy techniques. We show that for secretions to move, air flow has to be high enough to overcome secretion resistance to motion. Moreover, the higher the pressure or the quicker it is applied, the higher is the air flow and thus the mobilization of secretions. However, pressures too high are efficient up to a point where airways compressions prevents air flow to increases any further. Generally, the first effects of manipulations is a decrease of the airway tree hydrodynamic resistance, thus improving ventilation even if secretions do not get out of the lungs. Also, some secretions might be pushed deeper into the lungs; this effect is stronger for high pressures and for mechanical chest physiotherapy. Finally, we propose and tested two adimensional numbers that depend on lung properties and that allow to measure the efficiency and comfort of a manipulation.
15 Feb 2015
AG-2015.02-2052
physics.med-ph
Letizia Mariotti, Nicholas Devaney
Many algorithms have been proposed to help clinicians evaluate cone density and spacing, as these may be related to the onset of retinal diseases. However, there has been no rigorous comparison of the performance of these algorithms. In addition, the performance of such algorithms is typically determined by comparison with human observers. Here we propose a technique to simulate realistic images of the cone mosaic. We use the simulated images to test the performance of two popular cone detection algorithms and we introduce an algorithm which is used by astronomers to detect stars in astronomical images. We use Free Response Operating Characteristic (FROC) curves to evaluate and compare the performance of the three algorithms. This allows us to optimize the performance of each algorithm. We observe that performance is significantly enhanced by up-sampling the images. We investigate the effect of noise and image quality on cone mosaic parameters estimated using the different algorithms, finding that the estimated regularity is the most sensitive parameter. This paper was published in JOSA A and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://www.opticsinfobase.org/abstract.cfm?msid=224577. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.
5 Feb 2015
AG-2015.01-1910
physics.med-ph
Chengguo Pang, Junkui Xu, Wuyuan Li, Weiwei Yan, Zeen Yao, Youwu Su
Microdosimetric single event spectra is a significant parameter in radiotherapy, which can be used to evaluate the biological effect of radiation fields. This paper simulated microscopic patterns of energy depositions for mixed radiation fields which are created by carbon ions with general purpose Monte Carlo code FLUKA. . Experimental measured lineal energy spectra produced by carbon ions of about 300MeV/u were chosen from literature to compared with the results from simulation one of the measurement set-up. In addition, the dose-weighted lineal energy spectra, frequency averaged lineal energy values and dose averaged lineal energy values of carbon ions from 120MeV/u to 430MeV/u of the measurement set-up were calculated, too. The results of this paper are meaningful for making treatment planning in carbon ion radiotherapy.
31 Jan 2015
AG-2015.01-1863
physics.med-ph
W. Ulmer
Friction incorporates the close connection between classical mechanics in irreversible thermodynamics. The translation to a quantum mechanical foundation is not trivial and requires a generalization of the Lagrange function. A change to electromagnetic circuits appears to more adequate, since the electric analogue (Ohms law) is related to scatter of electrons at lattice vibrations.
30 Jan 2015
AG-2015.01-1868
physics.med-ph
Elias Kellner, Bibek Dhital, Marco Reisert
Gibbs-ringing is a well known artifact which manifests itself as spurious oscillations in the vicinity of sharp image transients, e.g. at tissue boundaries. The origin can be seen in the truncation of k-space during MRI data-acquisition. Consequently, correction techniques like Gegenbauer reconstruction or extrapolation methods aim at recovering these missing data. Here, we present a simple and robust method which exploits a different view on the Gibbs-phenomena. The truncation in k-space can be interpreted as a convolution with a sinc-function in image space. Hence, the severity of the artifacts depends on how the sinc-function is sampled. We propose to re-interpolate the image based on local, subvoxel shifts to sample the ringing pattern at the zero-crossings of the oscillating sinc-function. With this, the artifact can effectively and robustly be removed with a minimal amount of smoothing.
30 Jan 2015
AG-2015.01-2685
physics.med-ph
A. Morozov, V. Solovov, F. Alves, V. Domingos, R. Martins, F. Neves, V. Chepel
Statistical event reconstruction techniques can give better results for gamma cameras than the traditional centroid method. However, implementation of such techniques requires detailed knowledge of the PMT light response functions. Here we describe an iterative technique which allows to obtain the response functions from flood irradiation data without imposing strict requirements on the spatial uniformity of the event distribution. A successful application of the technique for medical gamma cameras is demonstrated using both simulated and experimental data. We show that this technique can be used for monitoring of the photomultiplier gain variations. An implementation of the iterative reconstruction technique capable of operating in real-time is also presented.
28 Jan 2015
AG-2015.01-1090
physics.med-ph
Tianren Wang, Yun Jing
This paper presents a numerical study on a fast marching method based back projection reconstruction algorithm for photoacoustic tomography in heterogeneous media. Transcranial imaging is used here as a case study. To correct for the phase aberration from the heterogeneity (i.e., skull), the fast marching method is adopted to compute the phase delay based on the known speed of sound distribution, and the phase delay is taken into account by the back projection algorithm for more accurate reconstructions. It is shown that the proposed algorithm is more accurate than the conventional back projection algorithm, but slightly less accurate than the time reversal algorithm particularly in the area close to the skull. However, the image reconstruction time for the proposed algorithm can be as little as 124 ms when implemented by a GPU (512 sensors, 21323 pixels reconstructed), which is two orders of magnitude faster than the time reversal reconstruction. The proposed algorithm, therefore, not only corrects for the phase aberration, but can be also potentially implemented in a real-time manner.
20 Jan 2015
AG-2015.01-1092
physics.med-ph
Alex Malins, Masahiko Machida, Kimiaki Saito
A letter to the editor of the Journal of Environmental Radioactivity on the article: E. Gasser, A. Nachab, A. Nourreddine, Ch. Roy, and A. Sellam, `Update of 40K and 226Ra and 232Th series $γ$-to-dose conversion factors for soil', J. Environ. Radioactiv. 138, 68-71 (2014), DOI: 10.1016/j.jenvrad.2014.08.002.
20 Jan 2015
AG-2015.01-1035
physics.med-ph
Wei Zhao, Jun Zhu, Luyao Wang
We provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profile for a set of CBCT images. A total-variation denoising algorithm designed specifically for Poisson signal is then applied to derive the final scatter distribution. Qualitatively and quantitatively evaluations using Monte Carlo (MC) simulations, experimental CBCT phantom data, and \emph{in vivo} human data acquired for a clinical image guided radiation therapy were performed. Results show that the proposed algorithm can significantly reduce scatter artifacts and recover the correct HU within either projection domain or image domain. Further test shows the method is robust with respect to segmentation procedure.
19 Jan 2015
AG-2015.01-1034
physics.med-ph
Wei Zhao, Stephen Brunner, Kai Niu, Sebastian Schafer, Kevin Royalty, Guang-Hong Chen
This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging, scatter radiation has increased dramatically compared to 2D imaging, leading to a degradation of image quality. In this study, we propose a scatter artifact correction strategy using an analytical convolution-based model whose free parameters are estimated using a rough estimation of scatter profiles from the acquired cone-beam projections. It was evaluated using Monte Carlo simulations with both monochromatic and polychromatic X-ray sources. The results demonstrated that the proposed method significantly reduced the scatter-induced shading artifacts and recovered CT numbers.
19 Jan 2015
AG-2015.01-2761
physics.med-ph
Kim Christensen, Kishan A. Manani, Nicholas S. Peters
Atrial fibrillation (AF) is the most common abnormal heart rhythm and the single biggest cause of stroke. Ablation, destroying regions of the atria, is applied largely empirically and can be curative but with a disappointing clinical success rate. We design a simple model of activation wavefront propagation on a structure mimicking the branching network architecture of heart muscle and show how AF emerges spontaneously as age-related parameters change. We identify regions responsible for the initiation and maintenance of AF, the ablation of which terminates AF. The simplicity of the model allows us to calculate analytically the risk of arrhythmia. This analytical result allows us to locate the transition in parameter space and highlights that the transition from regular to fibrillatory behaviour is a finite-size effect present in systems of any size. These clinically testable predictions might inform ablation therapies and arrhythmic risk assessment.
14 Jan 2015
AG-2015.01-778
physics.med-ph
Bernard L. Jones, David Westerly, Moyed Miften
Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. We developed and validated a method which uses these projections to determine the trajectory of and dose to highly mobile tumors during each fraction of treatment. Methods: CBCT images of a respiration phantom were acquired, the trajectory of which mimicked a lung tumor with high amplitude (up to 2.5 cm) and hysteresis. A template-matching algorithm was used to identify the location of a steel BB in each CBCT projection, and a Gaussian probability density function for the absolute BB position was calculated which best fit the observed trajectory of the BB in the imager geometry. Two modifications of the trajectory reconstruction were investigated: first, using respiratory phase information to refine the trajectory estimation (Phase), and second, using the Monte Carlo (MC) method to sample the estimated Gaussian tumor position distribution. Results: With all methods, the mean position of the BB was determined with accuracy better than 0.1 mm, and trajectory errors averaged 3.8$\pm$1.1% of the marker amplitude. Dosimetric calculations using Phase methods were more accurate, with mean absolute error less than 0.5%, and with error less than 1% in the highest-noise trajectory. MC-based trajectories prevent the over-estimation of dose, but when viewed in an absolute sense, add a small amount of dosimetric error (<0.1%). Conclusions: Marker trajectory and target dose-of-the-day were accurately calculated using CBCT projections. This technique provides a method to evaluate highly-mobile tumors using ordinary CBCT data, and could facilitate better strategies to mitigate or compensate for motion during SBRT.
14 Jan 2015
AG-2015.01-716
physics.med-ph
Brian Neilly, Sarah Allen, Jim Ballinger, John Buscombe, Rob Clarke, Beverley Ellis, Glenn Flux, Louise Fraser, Adrian Hall, Hywel Owen, Audrey Paterson, Alan Perkins, Andrew Scarsbrook
The UK has no research nuclear reactors and relies on the importation of 99Mo and other medical radioisotopes (e.g. Iodine-131) from overseas (excluding PET radioisotopes). The UK is therefore vulnerable not only to global shortages, but to problems with shipping and importation of the products. In this context Professor Erika Denton UK national Clinical Director for Diagnostics requested that the British Nuclear Medicine Society lead a working group with stakeholders including representatives from the Science & Technology Facilities Council (STFC) to prepare a report. The group had a first meeting on 10 April 2013 followed by a working group meeting with presentations on 9th September 2013 where the scope of the work required to produce a report was agreed. The objectives of the report are: to describe the status of the use of medical radioisotopes in the UK; to anticipate the potential impact of shortages for the UK; to assess potential alternative avenues of medical radioisotope production for the UK market; and to explore ways of mitigating the impact of medical radioisotopes on patient care pathways. The report incorporates details of a visit to the Cyclotron Facilities at Edmonton, Alberta and at TRIUMF, Vancouver BC in Canada by members of the report team.
13 Jan 2015
AG-2015.01-703
physics.med-ph
Gennaro Gelao, Roberto Marani, Vittorio M. N. Passaro, Anna Gina Perri
In this paper we present an acquisition chain for the measurement of blood arterial pressure based on the oscillometric method. This method does not suffer from any limitation as the well-known auscultatory method and it is suited for wearable health monitoring systems. The device uses a pressure sensor whose signal is filtered, digitalized and analyzed by a microcontroller. Local analysis allows the evaluation of the systolic and diastolic pressure values which can be used for local alarms, data collection and remote monitoring.
13 Jan 2015
AG-2015.01-181
physics.med-ph
O. Actis, D. Meer, S. König
An on-line beam position monitoring and regular beam stability tests are of utmost importance for the Quality Assurance (QA) of the patient treatment at any particle therapy facility. The Gantry$\hspace{0.5 mm}2$ at the Paul Scherrer Institute uses a strip ionization chamber for the on-line beam position verification. The design of the strip chamber placed in the beam in front of the patient allows for a small beam penumbra in order to achieve a high-quality lateral beam delivery. The position error of 1 mm in a lateral plane (plane perpendicular to the beam direction) can result in a dose inhomogeneity of more than $5 \%$. Therefore the goal of Gantry 2 commissioning was to reach a sub-millimeter level of the reconstruction accuracy in order to bring a dose uncertainty to a level of $1 \%$. In fact, we observed that for beams offered by Gantry 2 signal profiles in a lateral plane can be reconstructed with a precision of 0.1 mm. This is a necessary criterion to perform a reliable patient treatment. The front end electronics and the whole data processing sequence have been optimized for minimizing the dead time in between two consecutive spots to about 2 ms: the charge collection is performed in about 1 ms, read-out takes place in about 100 $μ$s while data verification and logging are completed in less than 1 ms.
6 Jan 2015
AG-2014.12-2114
physics.med-ph
Kun Wang, Thomas Matthews, Fatima Anis, Cuiping Li, Neb Duric, Mark A. Anastasio
Ultrasound computed tomography (USCT) holds great promise for improving the detection and management of breast cancer. Because they are based on the acoustic wave equation, waveform inversion-based reconstruction methods can produce images that possess improved spatial resolution properties over those produced by ray-based methods. However, waveform inversion methods are computationally demanding and have not been applied widely in USCT breast imaging. In this work, source encoding concepts are employed to develop an accelerated USCT reconstruction method that circumvents the large computational burden of conventional waveform inversion methods. This method, referred to as the waveform inversion with source encoding (WISE) method, encodes the measurement data using a random encoding vector and determines an estimate of the sound speed distribution by solving a stochastic optimization problem by use of a stochastic gradient descent algorithm. Both computer-simulation and experimental phantom studies are conducted to demonstrate the use of the WISE method. The results suggest that the WISE method maintains the high spatial resolution of waveform inversion methods while significantly reducing the computational burden.
30 Dec 2014
AG-2014.12-2203
physics.med-ph
Francesco Collamati, Alessandra Pepe, Fabio Bellini, Valerio Bocci, Marta Cremonesi, Erika De Lucia, Mahila Ferrari, Paola M. Frallicciardi, Chiara M. Grana, Michela Marafini, Ilaria Mattei, Silvio Morganti, Vincenzo Patera, Luca Piersanti, Luigi Recchia, Andrea Russomando, Alessio Sarti, Adalberto Sciubba, Martina Senzacqua, Elena Solfaroli Camillocci, Cecilia Voena, Riccardo Faccini
A novel radio guided surgery (RGS) technique for cerebral tumors using $β^{-}$ radiation is being developed. Checking the availability of a radio-tracer that can deliver a $β^{-}$ emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study of the RGS technique in these cases.
23 Dec 2014
AG-2014.12-1697
physics.med-ph
S. Kumar, S. K. Majumdar
We present results of Raman spectroscopic studies of urine to determine the suitability of near-infrared Raman spectroscopy for quantitative estimation of urinary urea. The Raman spectra were acquired from the urine samples with an inbuilt Raman spectroscopy setup that employs a 785-nm diode laser as the Raman excitation source. A multivariate algorithm based on partial least square (PLS) regression was developed to predict the concentration of urea depending on the measured sets of Raman spectra and the reference urea concentration. The computed results shows that Raman spectroscopy in amalgamation with PLS-based multivariate chemometric algorithm can detect urea in urine samples with an accuracy of >90 %
23 Dec 2014
AG-2014.12-1698
physics.med-ph
S. Kumar, S. K. Majumdar
Urea and creatinine are two important diagnostic components of urine. The study of creatinine in liquid phase is difficult due to its feeble concentration in urine. To bring down the detection limit, Raman spectroscopy of dried urine samples was employed. Raman studies in association with partial least square algorithm of artificial urine samples gave improved results in dried phase as compared to liquid phase. These findings were further validated on real urine samples.
23 Dec 2014
AG-2014.12-1808
physics.med-ph
Matthew Getzin, Lars Gjesteby, Yen-Jun Chuang, Scott McCallum, Wenxiang Cong, Chao Wang, Zhengwei Pan, Guohao Dai, Ge Wang
CT and MRI are the two most widely used imaging modalities in healthcare, each with its own merits and drawbacks. Combining these techniques in one machine could provide unprecedented resolution and sensitivity in a single scan, and serve as an ideal platform to explore physical coupling of x-ray excitation and magnetic resonance. Molecular probes such as functionalized nanophosphors present an opportunity to demonstrate a synergy between these modalities. However, a simultaneous CT-MRI scanner does not exist at this moment. As a pilot study, here we propose a mechanism in which water solutions containing LiGa5O8:Cr3+ nanophosphors can be excited with x-rays to store energy, and these excited particles may subsequently influence the T2 relaxation times of the solutions so that a difference in T2 can be measured by MRI before and after x-ray excitation. The trends seen in our study suggest that a measurable effect may exist from x-ray excitation of the nanophosphors. However, there are several experimental conditions that hinder the clarity of the results to be statistically significant up to a commonly accepted level (p=0.05), including insoluble nanoparticles and inter-scan variability. Nevertheless, the initial results from our experiments seem a consistent and inspiring story that x-rays modify MRI T2 values around nanophosphors. Upon availability of soluble nanophosphors, we will repeat our experiments to confirm these observations.
23 Dec 2014
AG-2014.12-1616
physics.med-ph
Houxun Miao, Andrew A. Gomella, Katherine J. Harmon, Eric E. Bennett, Nicholas Chedid, Alireza Panna, Priya Bhandarkar, Han Wen
Low dose, high contrast x-ray imaging is of general interest in medical diagnostic applications. X-ray Mach-Zehnder interferometers using collimated synchrotron beams demonstrate the highest levels of phase contrast under a given exposure dose. However, common x-ray sources emit divergent cone beams. Here, we developed a spherical-wave inline Mach-Zehnder interferometer for phase contrast imaging over an extended area with a broadband and divergent source. The first tabletop system was tested in imaging experiments of a mammographic accreditation phantom and various biological specimens. The noise level of the phase contrast images at a clinical radiation dose corresponded to a 6 nano radian bending of the x-ray wavefront. Un-resolved structures with conventional radiography and near-field interferometer techniques became visible at a fraction of the radiation dose.
21 Dec 2014
AG-2014.12-1504
physics.med-ph
Jamie A. Dean, Liam C. Welsh, Kevin J. Harrington, Christopher M. Nutting, Sarah L. Gulliford
In radiotherapy for head and neck cancer, the radiation dose delivered to the pharyngeal mucosa (mucosal lining of the throat) is thought to be a major contributing factor to dysphagia (swallowing dysfunction), the most commonly reported severe toxicity. There is a variation in the severity of dysphagia experienced by patients. Understanding the role of the dose distribution in dysphagia would allow improvements in the radiotherapy technique to be explored. The 3D dose distributions delivered to the pharyngeal mucosa of 249 patients treated as part of clinical trials were reconstructed. Pydicom was used to extract DICOM (digital imaging and communications in medicine) data (the standard file formats for medical imaging and radiotherapy data). NumPy and SciPy were used to manipulate the data to generate 3D maps of the dose distribution delivered to the pharyngeal mucosa and calculate metrics describing the dose distribution. Multivariate predictive modelling of severe dysphagia, including descriptions of the dose distribution and relevant clinical factors, was performed using Pandas and SciKit-Learn. Matplotlib and Mayavi were used for 2D and 3D data visualisation. A support vector classification model, with feature selection using randomised logistic regression, to predict radiation-induced severe dysphagia, was trained. When this model was independently validated, the area under the receiver operating characteristic curve was 0.54. The model has poor predictive power and work is ongoing to improve the model through alternative feature engineering and statistical modelling approaches.
19 Dec 2014
AG-2014.12-1138
physics.med-ph
Ge Wang
Gauge invariability guarantees the same form of the Maxwell equations in different coordinate systems, and is instrumental for electromagnetic cloaking to hide a region of interest (ROI) perfectly. On the other hand, interior tomography is to reconstruct an ROI exactly. In this article, the recent results in these two disconnected areas are brought together to justify the general interior tomography principle. Several opportunities are suggested for tomographic research.
15 Dec 2014
AG-2014.12-875
physics.med-ph
Jose Carlos Serufo Filho, Renato Camargos Couto, Tania Moreira Grillo
The management requires a hospital organization to provision their costs/expenses with tools that approximate reality. The task of measuring productivity can be complex and uncertain, several methods are tested and the use of the DRG has been efficient, being used to assess the productivity through clinical outcomes. Cross-sectional study evaluated 145.710 hospitalizations in the period 2012-2014, using the DRG methodology for measuring productivity from the median length of hospitalization. When we group all hospitalizations in clinical (37.6%) and surgical (62.4%), multiple analyzes could be made according to this criterion. The DRG as a tool for prediction of hospital days is an effective alternative, thereby contributing to the control of productivity that directly influences the costs of hospital expenses and product and service quality.
12 Dec 2014
AG-2014.12-743
physics.med-ph
Ehsan Salari, Jan Unkelbach, Thomas Bortfeld
In concurrent chemoradiotherapy, chemotherapeutic agents are administered during the course of radiotherapy to enhance the primary tumor control. However, that often comes at the expense of increased risk of normal-tissue complications. The additional biological damage is mainly attributed to two mechanisms of action, which are the independent cytotoxic activity of chemotherapeutic agents and their interactive cooperation with radiation. The goal of this study is to develop a mathematical framework to obtain drug and radiation administration schedules that maximize the therapeutic gain for concurrent chemoradiotherapy. In particular, we analyze the impact of incorporating these two mechanisms into the radiation fractionation problem. Considering each mechanism individually, we first derive closed-form expressions for the optimal radiation fractionation regimen and the corresponding drug administration schedule. We next study the case in which both mechanisms are simultaneously present and develop a dynamic programming framework to determine optimal treatment regimens. Results show that those chemotherapeutic agents that interact with radiation may change optimal radiation fractionation regimens. Moreover, administration of chemotherapeutic agents possessing both mechanisms may give rise to optimal non-stationary radiation fractionation schemes.
11 Dec 2014
AG-2014.11-3928
physics.med-ph
Aafke C. Kraan, G. Battistoni, N. Belcari, N. Camarlinghi, F. Cappucci, M. Ciocca, A. Ferrari, S. Ferretti, A. Mairani, S. Molinelli, M. Pullia, A. Retico, P. Sala, G. Sportelli, A. Del Guerra, V. Rosso
PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements for proton range verification in phantoms, performed at the CNAO particle therapy treatment center in Pavia, Italy, with our 10 x 10 cm^2 planar PET prototype DoPET. PMMA phantoms were irradiated with mono-energetic proton beams and clinical treatment plans, and PET data were acquired during and shortly after proton irradiation. We created 1-D profiles of the beta+ activity along the proton beam-axis, and evaluated the difference between the proximal rise and the distal fall-off position of the activity distribution. A good agreement with FLUKA Monte Carlo predictions was obtained. We also assessed the system response when the PMMA phantom contained an air cavity. The system was able to detect these cavities quickly after irradiation.
26 Nov 2014
AG-2014.11-1887
physics.med-ph
John S. Ginn, Heather M. Whitney
Long pulse durations necessary in selective inversion recovery (SIR) experiments along with radiation damping (RD) introduce difficulties in quantitative nuclear magnetic resonance measurements, such as those that allow for the determination of a sample's characteristics, including the rates that govern magnetization transfer. Because of these influences, the assumption of perfect inversion is invalid. In this work, we present data that demonstrates that long pulse durations as well as RD cause difficulties in SIR experiments performed on simple one-spin systems, indicating that they will be problematic for multiple-spin systems as well. These results emphasize the importance of understanding the evolution of magnetization for all time points throughout an experiment used in quantitative NMR measurements. Furthermore, experimental parameters must be chosen carefully and understood completely.
26 Nov 2014
AG-2014.11-1486
physics.med-ph
Omid Ghasemalizadeh, Mohammad Rreza Mirzaee, Bahar Firoozabadi, Behrang Sajadi, Ali Zolfonoon
Lumped method (Electrical analogy) is a quick and easy way to model human cardiovascular system. In this paper Lumped method is used for simulating a complete model. It describes a 36-vessel model and cardiac system of human body with details that could show hydrodynamic parameters of cardiovascular system. Also this paper includes modeling of pulmonary, atrium, left and right ventricles with their equivalent circuits. Exact modeling of right and left ventricles pressure with division of ascending aorta into 27 segments increases the accuracy of our simulation. In this paper we show that a calculated pressure for aorta from our complex circuit is near to measured pressure by using advanced medical instruments. Also it is shown that pressure graph from brachial is so near to aortic pressure because of this its pressure signal is usable instead of aortic pressure. Furthermore, obstruction in ascending aorta, brachial and its effects has been showed in different figures.
21 Nov 2014
AG-2014.11-1370
physics.med-ph
Omid Ghasemalizadeh, Mohammad Reza Mirzaee, Bahar Firoozabadi, Kamran Hassani
Electrical analogy (Lumped method) is an easy way to model human cardiovascular system. In this paper Lumped method is used for simulating a complete model. It describes a 36-vessel model and cardiac system of human body with details that could show hydrodynamic parameters of cardiovascular system. Also this paper includes modeling of pulmonary, atrium, left and right ventricles with their equivalent circuits. Exact modeling of right and left ventricles pressure increases the accuracy of our simulation. In this paper we show that a calculated pressure for aorta from our complex circuit is near to measured pressure by using advanced medical instruments.
19 Nov 2014
AG-2014.11-1061
physics.med-ph
Qinghui Zhang, Weijun Xiong, M. Chan, Y. Song, C. Burman
Rotational setup errors are usually neglected in most clinical centers. An analytical formula is developed to determine the extra margin between clinical target volume (CTV) and planning target volume (PTV) to account for setup errors. The proposed formula corrects for both translational and rotational setup errors and then incorporated into margin determination for PTV.
16 Nov 2014
AG-2014.11-3299
physics.med-ph
Lev A. Matveev, Vladimir Yu. Zaitsev, Grigory V. Gelikonov, Alexandr L. Matveyev, Alexander A. Moiseev, Sergey Ksenofontov, Valentin M. Gelikonov, Valentin Demidov, Alex Vitkin
We propose a novel OCT-based method for visualizing microvasculature in 3D using reference-free processing of individual complex-valued B-scans with highly overlapped A-scans. In the lateral direction of such a B-scan, the amplitude and phase of speckles corresponding to vessel regions exhibit faster variability, and thus can be detected without comparison with other B-scans recorded in the same plane. This method combines elements of several existing OCT angiographic approaches, and exhibits: (i) enhanced robustness with respect to bulk tissue motion with frequencies up to tens of Hz; (ii) resolution of microcirculation images equal to that of structural images and (iii) possibility of quantifying the vessels in terms of their decorrelation rates.
1 Nov 2014
AG-2014.10-2112
physics.med-ph
Hao Yan, Xuanqin Mou, Yanbo Zhang, Maria Zankl
In the scatter correction for x-ray Cone Beam (CB) CT, the single-scan scheme with moving Beam Stop Array (BSA) offers reliable scatter measurement with low dose, and by using Projection Correlation based View Interpolation (PC-VI), the primary fluence shaded by the moving BSA (during scatter measurement) could be recovered with high accuracy. However, the moving BSA may increase the mechanical burden in real applications. For better practicability, in this paper we proposed a PC-VI based single-scan scheme with a ring-shaped stationary BSA, which serves as a virtual moving BSA during CB scan, so the shaded primary fluence by this stationary BSA can be also well recovered by PC-VI. The principle in designing the whole system is deduced and evaluated. The proposed scheme greatly enhances the practicability of the single-scan scatter correction scheme.
30 Oct 2014
AG-2014.10-2051
physics.med-ph
Hao Yan, Xuanqin Mou, Shaojie Tang, Qiong Xu
In this paper, an improved scatter correction with moving beam stop array (BSA) for x-ray cone beam (CB) CT is proposed. Firstly, correlation between neighboring CB views is deduced based on John's Equation. Then, correlation-based algorithm is presented to complement the incomplete views by using the redundancy (over-determined information) in CB projections. Finally, combining the algorithm with scatter correction method using moving BSA, where part of primary radiation is blocked and incomplete projections are acquired, an improved correction method is proposed. Effectiveness and robustness is validated by Monte Carlo (MC) simulation with EGSnrc on humanoid phantom.
30 Oct 2014
AG-2014.10-2030
physics.med-ph
Wen Wang, Meng-yun Cheng, Peng-cheng Long, Li-qin Hu
The specific absorbed fractions (SAF) for self- and cross-irradiation are effective tools for the internal dose estimation of inhalation and ingestion intakes of radionuclides. A set of SAFs of photon and electron were calculated using the Rad-HUMAN phantom, a computational voxel phantom of Chinese adult female and created using the color photographic image of the Chinese Visible Human (CVH) data set. The model can represent most of Chinese adult female anatomical characteristics and can be taken as an individual phantom to investigate the difference of internal dose with Caucasians. In this study, the emission of mono-energetic photons and electrons of 10keV to 4MeV energy were calculated using the Monte Carlo particle transport calculation code MCNP. Results were compared with the values from ICRP reference and ORNL models. The results showed that SAF from Rad-HUMAN have the similar trends but larger than those from the other two models. The differences were due to the racial and anatomical differences in organ mass and inter-organ distance. The SAFs based on the Rad-HUMAN phantom provide an accurate and reliable data for internal radiation dose calculations for Chinese female.
30 Oct 2014
AG-2014.10-1288
physics.med-ph
Saptarshi Das, Koushik Maharatna
In this paper, an incommensurate fractional order (FO) model has been proposed to generate ECG like waveforms. Earlier investigation of ECG like waveform generation is based on two identical Van-der Pol (VdP) family of oscillators which are coupled by time delays and gains. In this paper, we suitably modify the three state equations corresponding to the nonlinear cross-product of states, time delay coupling of the two oscillators and low-pass filtering, using the concept of fractional derivatives. Our results show that a wide variety of ECG like waveforms can be simulated from the proposed generalized models, characterizing heart conditions under different physiological conditions. Such generalization of the modelling of ECG waveforms may be useful to understand the physiological process behind ECG signal generation in normal and abnormal heart conditions. Along with the proposed FO models, an optimization based approach is also presented to estimate the VdP oscillator parameters for representing a realistic ECG like signal.
20 Oct 2014
AG-2014.10-1396
physics.med-ph
George Koulaouzidis, Saptarshi Das, Grazia Cappiello, Evangelos B. Mazomenos, Koushik Maharatna, John Morgan
Ventricular arrhythmias comprise a group of disorders which manifest clinically in a variety of ways from ventricular premature beats (VPB) and no sustained ventricular tachycardia (in healthy subjects) to sudden cardiac death due to ventricular tachyarrhythmia in patients with and/or without structural heart disease. Ventricular fibrillation (VF) and ventricular tachycardia (VT) are the most common electrical mechanisms for cardiac arrest. Accurate and automatic recognition of these arrhythmias from electrocardiography (ECG) is a crucial task for medical professionals. The purpose of this research is to develop a new index for the differential diagnosis of normal sinus rhythm (SR) and ventricular arrhythmias, based on phase space reconstruction (PSR).
20 Oct 2014